Development times
Kentmere Pan 100 in Ilford Ilfotec RT Rapid
6 published times at 1+1+2, 1+1+5, rated at EI 50–200, 26.0 °C. Each one is linked to the datasheet or chart it was read from.
At box speed
0:50
Speed
EI 100
Dilution
1+1+2
Temperature
26.0 °C
Every published time
| Developer | Dilution | EI | Temp | Time | Agitation | Source |
|---|---|---|---|---|---|---|
| Ilfotec RT Rapid | 1+1+2 | 50 pull 1 stop | 26.0 °C | 0:45 | — |
Verified
Datasheet
|
| Ilfotec RT Rapid | 1+1+5 | 50 pull 1 stop | 26.0 °C | 1:00 | — |
Verified
Datasheet
|
| Ilfotec RT Rapid | 1+1+2 | 100 | 26.0 °C | 0:50 | — |
Verified
Datasheet
|
| Ilfotec RT Rapid | 1+1+5 | 100 | 26.0 °C | 1:10 | — |
Verified
Datasheet
|
| Ilfotec RT Rapid | 1+1+2 | 200 push 1 stop | 26.0 °C | 1:00 | — |
Verified
Datasheet
|
| Ilfotec RT Rapid | 1+1+5 | 200 push 1 stop | 26.0 °C | 1:30 | — |
Verified
Datasheet
|