Delta 3200 Professional 1+19 400 pull 3 stops 24.0 °C 5:00 —
Verified Datasheet
Delta 3200 Professional 1+19 800 pull 2 stops 24.0 °C 6:00 —
Verified Datasheet
Delta 3200 Professional 1+19 1600 pull 1 stop 24.0 °C 7:00 —
Verified Datasheet
Delta 3200 Professional 1+19 3200 24.0 °C 10:30 —
Verified Datasheet
Delta 3200 Professional 1+9 3200 24.0 °C 5:30 —
Verified Datasheet
Delta 3200 Professional 1+9 6400 push 1 stop 24.0 °C 8:30 —
Verified Datasheet
Ilford HP5+ 1+9 3200 push 3 stops 20.0 °C 12:30 —
Unverified Datasheet
Ilford HP5+ 1+9 3200 push 3 stops 20.0 °C 12:30 —
Unverified Datasheet
Ilford HP5+ 1+9 3200 push 3 stops 20.0 °C 12:30 —
Unverified Datasheet
Pan F Plus 1+19 50 20.0 °C 4:00 —
Verified Datasheet
Pan F Plus 1+29 50 20.0 °C 5:30 —
Verified Datasheet
FP4 Plus 1+19 50 pull 1.25 stops 20.0 °C 6:00 —
Verified Datasheet
FP4 Plus 1+19 125 20.0 °C 8:00 —
Verified Datasheet
FP4 Plus 1+19 200 push 0.75 stops 20.0 °C 9:00 —
Verified Datasheet
FP4 Plus 1+29 50 pull 1.25 stops 20.0 °C 8:00 —
Verified Datasheet
FP4 Plus 1+29 125 20.0 °C 12:00 —
Verified Datasheet
FP4 Plus 1+9 125 20.0 °C 4:00 —
Verified Datasheet
FP4 Plus 1+9 200 push 0.75 stops 20.0 °C 5:00 —
Verified Datasheet
Ilford Delta 100 Pro 1+19 50 pull 1 stop 20.0 °C 5:00 —
Verified Datasheet
Ilford Delta 100 Pro 1+19 100 20.0 °C 6:00 —
Verified Datasheet
Ilford Delta 100 Pro 1+19 200 push 1 stop 20.0 °C 8:00 —
Verified Datasheet
Ilford Delta 100 Pro 1+29 50 pull 1 stop 20.0 °C 5:30 —
Verified Datasheet
Ilford Delta 100 Pro 1+29 100 20.0 °C 7:30 —
Verified Datasheet
Ilford Delta 100 Pro 1+29 200 push 1 stop 20.0 °C 10:00 —
Verified Datasheet
Ilford HP5+ 1+19 400 20.0 °C 6:30 —
Verified Datasheet
Ilford HP5+ 1+19 800 push 1 stop 20.0 °C 9:30 —
Verified Datasheet
Ilford HP5+ 1+19 1600 push 2 stops 20.0 °C 14:00 —
Verified Datasheet
Ilford HP5+ 1+29 400 20.0 °C 9:00 —
Verified Datasheet
Ilford HP5+ 1+9 400 20.0 °C 3:30 —
Verified Datasheet
Ilford HP5+ 1+9 800 push 1 stop 20.0 °C 5:00 —
Verified Datasheet
Ilford HP5+ 1+9 1600 push 2 stops 20.0 °C 7:30 —
Verified Datasheet
Ilford HP5+ 1+9 3200 push 3 stops 20.0 °C 11:00 —
Verified Datasheet
SFX 200 1+19 200 20.0 °C 9:00 —
Verified Datasheet
SFX 200 1+19 400 push 1 stop 20.0 °C 13:00 —
Verified Datasheet
SFX 200 1+19 800 push 2 stops 20.0 °C 19:00 —
Verified Datasheet
SFX 200 1+29 200 20.0 °C 11:00 —
Verified Datasheet
SFX 200 1+9 200 20.0 °C 5:00 —
Verified Datasheet
SFX 200 1+9 400 push 1 stop 20.0 °C 7:00 —
Verified Datasheet
SFX 200 1+9 800 push 2 stops 20.0 °C 10:30 —
Verified Datasheet
Delta 400 Professional 1+19 200 pull 1 stop 20.0 °C 5:00 —
Verified Datasheet
Delta 400 Professional 1+19 400 20.0 °C 7:30 —
Verified Datasheet
Delta 400 Professional 1+19 800 push 1 stop 20.0 °C 10:00 —
Verified Datasheet
Delta 400 Professional 1+19 1600 push 2 stops 20.0 °C 13:30 —
Verified Datasheet
Delta 400 Professional 1+29 200 pull 1 stop 20.0 °C 8:30 —
Verified Datasheet
Delta 400 Professional 1+29 400 20.0 °C 11:30 —
Verified Datasheet
Delta 400 Professional 1+29 800 push 1 stop 20.0 °C 17:00 —
Verified Datasheet
Delta 400 Professional 1+9 320 pull 0.25 stops 20.0 °C 4:00 —
Verified Datasheet
Delta 400 Professional 1+9 800 push 1 stop 20.0 °C 5:30 —
Verified Datasheet
Delta 400 Professional 1+9 1600 push 2 stops 20.0 °C 7:30 —
Verified Datasheet
Delta 400 Professional 1+9 3200 push 3 stops 20.0 °C 13:00 —
Verified Datasheet
Delta 400 Professional 1+19 200 pull 1 stop 24.0 °C 4:00 —
Verified Datasheet
Delta 400 Professional 1+19 400 24.0 °C 5:00 —
Verified Datasheet
Delta 400 Professional 1+19 800 push 1 stop 24.0 °C 7:00 —
Verified Datasheet
Delta 400 Professional 1+19 1600 push 2 stops 24.0 °C 10:00 —
Verified Datasheet
Delta 400 Professional 1+29 200 pull 1 stop 24.0 °C 5:30 —
Verified Datasheet
Delta 400 Professional 1+29 400 24.0 °C 7:30 —
Verified Datasheet
Delta 400 Professional 1+29 800 push 1 stop 24.0 °C 11:00 —
Verified Datasheet
Delta 400 Professional 1+29 1600 push 2 stops 24.0 °C 16:00 —
Verified Datasheet
Delta 400 Professional 1+9 800 push 1 stop 24.0 °C 4:30 —
Verified Datasheet
Delta 400 Professional 1+9 1600 push 2 stops 24.0 °C 5:30 —
Verified Datasheet
Delta 400 Professional 1+9 3200 push 3 stops 24.0 °C 8:00 —
Verified Datasheet
Delta 3200 Professional 1+19 400 pull 3 stops 20.0 °C 6:00 —
Verified Datasheet
Delta 3200 Professional 1+19 800 pull 2 stops 20.0 °C 7:30 —
Verified Datasheet
Delta 3200 Professional 1+19 1600 pull 1 stop 20.0 °C 9:00 —
Verified Datasheet
Delta 3200 Professional 1+19 3200 20.0 °C 14:30 —
Verified Datasheet
Delta 3200 Professional 1+9 1600 pull 1 stop 20.0 °C 5:00 —
Verified Datasheet
Delta 3200 Professional 1+9 3200 20.0 °C 8:00 —
Verified Datasheet
Delta 3200 Professional 1+9 6400 push 1 stop 20.0 °C 13:00 —
Verified Datasheet
Pan 100 1+19 50 pull 1 stop 20.0 °C 5:30 —
Verified Datasheet
Pan 100 1+19 100 20.0 °C 7:00 —
Verified Datasheet
Pan 100 1+19 200 push 1 stop 20.0 °C 8:00 —
Verified Datasheet
Pan 100 1+29 50 pull 1 stop 20.0 °C 7:30 —
Verified Datasheet
Pan 100 1+29 100 20.0 °C 11:00 —
Verified Datasheet
Pan 100 1+9 100 20.0 °C 4:00 —
Verified Datasheet
Pan 100 1+9 200 push 1 stop 20.0 °C 5:00 —
Verified Datasheet
Pan 200 1+19 100 pull 1 stop 20.0 °C 4:45 —
Verified Datasheet
Pan 200 1+19 200 20.0 °C 6:00 —
Verified Datasheet
Pan 200 1+19 400 push 1 stop 20.0 °C 7:30 —
Verified Datasheet
Pan 200 1+29 100 pull 1 stop 20.0 °C 7:00 —
Verified Datasheet
Pan 200 1+29 200 20.0 °C 10:30 —
Verified Datasheet
Pan 200 1+9 200 20.0 °C 4:00 —
Verified Datasheet
Pan 200 1+9 400 push 1 stop 20.0 °C 4:45 —
Verified Datasheet
'Y' 1+19 100 20.0 °C 8:00 —
Verified Datasheet
'V' 1+19 100 20.0 °C 8:00 —
Verified Datasheet
Pan 100 1+19 50 pull 1 stop 20.0 °C 6:00 —
Unverified Datasheet
Pan 100 1+19 100 20.0 °C 8:00 —
Unverified Datasheet
Pan 100 1+19 200 push 1 stop 20.0 °C 9:00 —
Unverified Datasheet
Pan 100 1+29 50 pull 1 stop 20.0 °C 8:00 —
Unverified Datasheet
Pan 100 1+29 100 20.0 °C 12:00 —
Unverified Datasheet
Pan 100 1+9 100 20.0 °C 4:00 —
Unverified Datasheet
Pan 100 1+9 200 push 1 stop 20.0 °C 5:00 —
Unverified Datasheet
Pan 400 1+19 200 pull 1 stop 20.0 °C 5:00 —
Unverified Datasheet
Pan 400 1+19 400 20.0 °C 6:00 —
Unverified Datasheet
Pan 400 1+19 800 push 1 stop 20.0 °C 9:00 —
Unverified Datasheet
Pan 400 1+19 1600 push 2 stops 20.0 °C 14:00 —
Unverified Datasheet
Pan 400 1+29 200 pull 1 stop 20.0 °C 7:00 —
Unverified Datasheet
Pan 400 1+29 400 20.0 °C 9:00 —
Unverified Datasheet
Pan 400 1+9 400 20.0 °C 3:00 —
Unverified Datasheet
Pan 400 1+9 800 push 1 stop 20.0 °C 5:00 —
Unverified Datasheet
Pan 400 1+9 1600 push 2 stops 20.0 °C 7:00 —
Unverified Datasheet
Pan 400 1+9 3200 push 3 stops 20.0 °C 11:00 —
Unverified Datasheet
Pan 400 1+19 400 20.0 °C 8:00 —
Verified Datasheet
Pan 400 1+19 800 push 1 stop 20.0 °C 12:30 —
Verified Datasheet
Pan 400 1+29 400 20.0 °C 11:00 —
Verified Datasheet
Pan 400 1+9 400 20.0 °C 4:30 —
Verified Datasheet
Pan 400 1+9 800 push 1 stop 20.0 °C 6:30 —
Verified Datasheet
'P' 1+19 100 20.0 °C 8:00 —
Verified Datasheet
'S' 1+19 50 20.0 °C 12:00 —
Verified Datasheet
Film Washi S 1+19 50 20.0 °C 12:00 —
Verified Datasheet
'F' 1+19 100 20.0 °C 8:00 —
Verified Datasheet
'A' 1+19 12 20.0 °C 7:00 —
Verified Datasheet
'D' 1+19 500 20.0 °C 4:00 —
Verified Datasheet
'G' 1+19 80 20.0 °C 6:00 —
Verified Datasheet
'K' 1+19 100 20.0 °C 5:30 —
Verified Datasheet
RPX 100 1+19 50 pull 1 stop 20.0 °C 5:30 —
Verified Datasheet
RPX 100 1+9 100 20.0 °C 4:00 —
Verified Datasheet
RPX 100 1+19 100 20.0 °C 7:00 —
Verified Datasheet
RPX 100 1+9 200 push 1 stop 20.0 °C 5:00 —
Verified Datasheet
RPX 100 1+19 200 push 1 stop 20.0 °C 8:00 —
Verified Datasheet
RPX 400 1+9 400 20.0 °C 4:30 —
Verified Datasheet
RPX 400 1+9 800 push 1 stop 20.0 °C 6:30 —
Verified Datasheet
RPX 400 1+19 400 20.0 °C 8:00 —
Verified Datasheet
RPX 400 1+19 800 push 1 stop 20.0 °C 12:30 —
Verified Datasheet
Retro 400S 1+9 400 20.0 °C 4:30 —
Verified Datasheet
Retro 400S 1+9 800 push 1 stop 20.0 °C 8:00 —
Verified Datasheet
Retro 400S 1+19 400 20.0 °C 6:30 —
Verified Datasheet
Retro 400S 1+19 800 push 1 stop 20.0 °C 12:30 —
Verified Datasheet

Dilutions

  • 1+9 1 + 9 water
  • 1+19 1 + 19 water
  • 1+29 1 + 29 water

Link to this page

Specification

Type
B&W developer
Form
Liquid concentrate
Capacity rolls per litre
—
Shelf life, unopened
—
Shelf life, opened
—

A dash means the figure has not been read off a datasheet. The reuse calculator depends on capacity, so a guess here would produce wrong answers silently.

0 reviews

Written by photographers, under their own profile — so you can see what they shoot before you weigh what they say.