Skip to content

Development times

Ilford Delta 400 Professional in Ilford Ilfotec LC29

22 published times at 1+19, 1+29, 1+9, rated at EI 200–3200, 20.0–24.0 °C. Each one is linked to the datasheet or chart it was read from.

At box speed

7:30

Speed

EI 400

Dilution

1+19

Temperature

20.0 °C

Every published time

Showing 22 of 22 published times.

Developer Dilution EI Temp Time Agitation Source
Ilfotec LC29 1+19 200 pull 1 stop 20.0 °C 5:00 —
Verified Datasheet
Ilfotec LC29 1+29 200 pull 1 stop 20.0 °C 8:30 —
Verified Datasheet
Ilfotec LC29 1+19 200 pull 1 stop 24.0 °C 4:00 —
Verified Datasheet
Ilfotec LC29 1+29 200 pull 1 stop 24.0 °C 5:30 —
Verified Datasheet
Ilfotec LC29 1+9 320 pull 0.25 stops 20.0 °C 4:00 —
Verified Datasheet
Ilfotec LC29 1+19 400 20.0 °C 7:30 —
Verified Datasheet
Ilfotec LC29 1+29 400 20.0 °C 11:30 —
Verified Datasheet
Ilfotec LC29 1+19 400 24.0 °C 5:00 —
Verified Datasheet
Ilfotec LC29 1+29 400 24.0 °C 7:30 —
Verified Datasheet
Ilfotec LC29 1+9 800 push 1 stop 20.0 °C 5:30 —
Verified Datasheet
Ilfotec LC29 1+19 800 push 1 stop 20.0 °C 10:00 —
Verified Datasheet
Ilfotec LC29 1+29 800 push 1 stop 20.0 °C 17:00 —
Verified Datasheet
Ilfotec LC29 1+9 800 push 1 stop 24.0 °C 4:30 —
Verified Datasheet
Ilfotec LC29 1+19 800 push 1 stop 24.0 °C 7:00 —
Verified Datasheet
Ilfotec LC29 1+29 800 push 1 stop 24.0 °C 11:00 —
Verified Datasheet
Ilfotec LC29 1+9 1600 push 2 stops 20.0 °C 7:30 —
Verified Datasheet
Ilfotec LC29 1+19 1600 push 2 stops 20.0 °C 13:30 —
Verified Datasheet
Ilfotec LC29 1+9 1600 push 2 stops 24.0 °C 5:30 —
Verified Datasheet
Ilfotec LC29 1+19 1600 push 2 stops 24.0 °C 10:00 —
Verified Datasheet
Ilfotec LC29 1+29 1600 push 2 stops 24.0 °C 16:00 —
Verified Datasheet
Ilfotec LC29 1+9 3200 push 3 stops 20.0 °C 13:00 —
Verified Datasheet
Ilfotec LC29 1+9 3200 push 3 stops 24.0 °C 8:00 —
Verified Datasheet