Pan 400
Nominal ISO
400
B&W negative
B&W
In production
Development times
| Developer | Dilution | EI | Temp | Time | Agitation | Source |
|---|---|---|---|---|---|---|
| Acufine | stock | 400 | 20.0 °C | 5:00 | — |
Unverified
Datasheet
|
| Rodinal | 1+25 | 400 | 20.0 °C | 6:00 | — |
Unverified
Datasheet
|
| Rodinal | 1+50 | 400 | 20.0 °C | 11:00 | — |
Unverified
Datasheet
|
| ID-11 | 1+1 | 400 | 20.0 °C | 13:00 | — |
Unverified
Datasheet
|
| ID-11 | 1+3 | 400 | 20.0 °C | 20:00 | — |
Unverified
Datasheet
|
| ID-11 | stock | 400 | 20.0 °C | 7:00 | — |
Unverified
Datasheet
|
| Ilfotec DD-X | 1+4 | 400 | 20.0 °C | 8:00 | — |
Unverified
Datasheet
|
| Ilfotec HC | 1+15 | 400 | 20.0 °C | 3:00 | — |
Unverified
Datasheet
|
| Ilfotec HC | 1+31 | 400 | 20.0 °C | 6:00 | — |
Unverified
Datasheet
|
| Ilfotec LC29 | 1+19 | 400 | 20.0 °C | 6:00 | — |
Unverified
Datasheet
|
| Ilfotec LC29 | 1+29 | 400 | 20.0 °C | 9:00 | — |
Unverified
Datasheet
|
| Ilfotec LC29 | 1+9 | 400 | 20.0 °C | 3:00 | — |
Unverified
Datasheet
|
| Microphen | 1+1 | 400 | 20.0 °C | 12:00 | — |
Unverified
Datasheet
|
| Microphen | 1+3 | 400 | 20.0 °C | 23:00 | — |
Unverified
Datasheet
|
| Microphen | stock | 400 | 20.0 °C | 6:00 | — |
Unverified
Datasheet
|
| Perceptol | 1+1 | 400 | 20.0 °C | 16:00 | — |
Unverified
Datasheet
|
| Perceptol | stock | 400 | 20.0 °C | 11:00 | — |
Unverified
Datasheet
|
| D-76 | 1+1 | 400 | 20.0 °C | 13:00 | — |
Unverified
Datasheet
|
| D-76 | 1+3 | 400 | 20.0 °C | 20:00 | — |
Unverified
Datasheet
|
| D-76 | stock | 400 | 20.0 °C | 7:00 | — |
Unverified
Datasheet
|
| HC-110 | Dilution A (1+15) | 400 | 20.0 °C | 3:00 | — |
Unverified
Datasheet
|
| HC-110 | Dilution B (1+31) | 400 | 20.0 °C | 6:00 | — |
Unverified
Datasheet
|
| T-Max Developer | 1+4 | 400 | 20.0 °C | 6:00 | — |
Unverified
Datasheet
|
| Ultrafin | 1+10 | 400 | 20.0 °C | 7:00 | — |
Unverified
Datasheet
|
| Ultrafin | 1+20 | 400 | 20.0 °C | 16:00 | — |
Unverified
Datasheet
|
| Ilfotec DD | 1+4 | 400 | 24.0 °C | 6:00 | — |
Unverified
Datasheet
|
| Ilfotec HC | 1+11 | 400 | 24.0 °C | 0:55 | — |
Unverified
Datasheet
|
| T-Max RS | stock | 400 | 24.0 °C | 4:00 | — |
Unverified
Datasheet
|
| Ilfotec RT Rapid | 1+1+2 | 400 | 26.0 °C | 1:00 | — |
Unverified
Datasheet
|
| Ilfotec RT Rapid | 1+1+5 | 400 | 26.0 °C | 1:10 | — |
Unverified
Datasheet
|
Development times by developer
15 developers
- Pan 400 in Acufine 4
- Pan 400 in D-76 9
- Pan 400 in HC-110 6
- Pan 400 in ID-11 9
- Pan 400 in Ilfotec DD 4
- Pan 400 in Ilfotec DD-X 5
- Pan 400 in Ilfotec HC 12
- Pan 400 in Ilfotec LC29 10
- Pan 400 in Ilfotec RT Rapid 8
- Pan 400 in Microphen 8
- Pan 400 in Perceptol 5
- Pan 400 in Rodinal 5
- Pan 400 in T-Max Developer 4
- Pan 400 in T-Max RS 3
- Pan 400 in Ultrafin 5
Link to this page
Specification
- Base
- Acetate
- Emulsion
- —
- Spectral sensitivity
-
Panchromatic — what this means
Sensitive to the whole visible spectrum, so colours turn into greys roughly the way the eye weighs them. This is what almost every general-purpose black and white film is. It has to be loaded and developed in complete darkness — no safelight is safe for it.
- Grain (RMS)
- —
- Resolving power line pairs / mm
- —
- Maximum density
- —
- Latitude over
- —
- Latitude under
- —
- First released
- —
A dash means the figure has not been read off a datasheet. Nothing here is estimated.
0 reviews
Written by photographers, under their own profile — so you can see what they shoot before you weigh what they say.
0 comments
Notes on how this behaves in practice — what it does in the field is worth as much as what the datasheet says.
No comments yet. Be the first to say how it actually behaves.