| Film | Verdünnung | EI | Temp. | Zeit | Kippen | Quelle |
|---|---|---|---|---|---|---|
| T-Max 400 | Dilution B (1+31) 18,0 °C | 400 | 5:45 | — | ||
| T-Max 400 | Dilution B (1+31) 20,0 °C | 400 | 5:15 | — | ||
| T-Max 400 | Dilution B (1+31) 21,0 °C | 400 | 4:45 | — | ||
| T-Max 400 | Dilution B (1+31) 22,0 °C | 400 | 4:30 | — | ||
| Pan F Plus | Dilution B (1+31) 20,0 °C | 50 | 4:00 | Ilford — 4 Kippungen alle 60 s | ||
| FP4 Plus | Dilution A (1+15) 20,0 °C | 125 | 4:30 | Ilford — 4 Kippungen alle 60 s | ||
| FP4 Plus | Dilution A (1+15) 20,0 °C | 200 Push um 0,75 Blenden | 6:00 | Ilford — 4 Kippungen alle 60 s | ||
| FP4 Plus | Dilution B (1+31) 20,0 °C | 50 Pull um 1,25 Blenden | 6:00 | Ilford — 4 Kippungen alle 60 s | ||
| FP4 Plus | Dilution B (1+31) 20,0 °C | 125 | 9:00 | Ilford — 4 Kippungen alle 60 s | ||
| FP4 Plus | Dilution B (1+31) 20,0 °C | 200 Push um 0,75 Blenden | 12:00 | Ilford — 4 Kippungen alle 60 s | ||
| Ilford Delta 100 Pro | Dilution B (1+31) 20,0 °C | 50 Pull um 1 Blende | 5:00 | Ilford — 4 Kippungen alle 60 s | ||
| Ilford Delta 100 Pro | Dilution B (1+31) 20,0 °C | 100 | 6:00 | Ilford — 4 Kippungen alle 60 s | ||
| Ilford Delta 100 Pro | Dilution B (1+31) 20,0 °C | 200 Push um 1 Blende | 8:00 | Ilford — 4 Kippungen alle 60 s | ||
| Ilford HP5+ | Dilution A (1+15) 20,0 °C | 400 | 2:30 | Ilford — 4 Kippungen alle 60 s | ||
| Ilford HP5+ | Dilution A (1+15) 20,0 °C | 800 Push um 1 Blende | 3:45 | Ilford — 4 Kippungen alle 60 s | ||
| Ilford HP5+ | Dilution A (1+15) 20,0 °C | 1600 Push um 2 Blenden | 5:30 | Ilford — 4 Kippungen alle 60 s | ||
| Ilford HP5+ | Dilution A (1+15) 20,0 °C | 3200 Push um 3 Blenden | 9:30 | Ilford — 4 Kippungen alle 60 s | ||
| Ilford HP5+ | Dilution B (1+31) 20,0 °C | 400 | 5:00 | Ilford — 4 Kippungen alle 60 s | ||
| Ilford HP5+ | Dilution B (1+31) 20,0 °C | 800 Push um 1 Blende | 7:30 | Ilford — 4 Kippungen alle 60 s | ||
| Ilford HP5+ | Dilution B (1+31) 20,0 °C | 1600 Push um 2 Blenden | 11:00 | Ilford — 4 Kippungen alle 60 s | ||
| SFX 200 | Dilution A (1+15) 20,0 °C | 200 | 5:00 | Ilford — 4 Kippungen alle 60 s | ||
| SFX 200 | Dilution A (1+15) 20,0 °C | 400 Push um 1 Blende | 7:00 | Ilford — 4 Kippungen alle 60 s | ||
| SFX 200 | Dilution A (1+15) 20,0 °C | 800 Push um 2 Blenden | 10:30 | Ilford — 4 Kippungen alle 60 s | ||
| SFX 200 | Dilution B (1+31) 20,0 °C | 200 | 9:00 | Ilford — 4 Kippungen alle 60 s | ||
| SFX 200 | Dilution B (1+31) 20,0 °C | 400 Push um 1 Blende | 13:00 | Ilford — 4 Kippungen alle 60 s | ||
| SFX 200 | Dilution B (1+31) 20,0 °C | 800 Push um 2 Blenden | 19:00 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution A (1+15) 20,0 °C | 320 Pull um 0,25 Blenden | 4:00 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution A (1+15) 20,0 °C | 800 Push um 1 Blende | 5:30 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution A (1+15) 20,0 °C | 1600 Push um 2 Blenden | 7:30 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution A (1+15) 20,0 °C | 3200 Push um 3 Blenden | 13:00 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution B (1+31) 20,0 °C | 200 Pull um 1 Blende | 5:00 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution B (1+31) 20,0 °C | 400 | 7:30 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution B (1+31) 20,0 °C | 800 Push um 1 Blende | 10:00 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution B (1+31) 20,0 °C | 1600 Push um 2 Blenden | 13:30 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution A (1+15) 24,0 °C | 800 Push um 1 Blende | 4:30 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution A (1+15) 24,0 °C | 1600 Push um 2 Blenden | 5:30 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution A (1+15) 24,0 °C | 3200 Push um 3 Blenden | 8:00 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution B (1+31) 24,0 °C | 200 Pull um 1 Blende | 4:00 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution B (1+31) 24,0 °C | 400 | 5:00 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution B (1+31) 24,0 °C | 800 Push um 1 Blende | 7:00 | Ilford — 4 Kippungen alle 60 s | ||
| Delta 400 Professional | Dilution B (1+31) 24,0 °C | 1600 Push um 2 Blenden | 10:00 | Ilford — 4 Kippungen alle 60 s | ||
| CHS 100 II | Dilution B (1+31) 20,0 °C | 100 | 5:30 | Kodak — 30 s zu Beginn, dann 5 s alle 30 s | ||
| CHS 100 II | Dilution D (1+39) 20,0 °C | 100 | 7:00 | Kodak — 30 s zu Beginn, dann 5 s alle 30 s | ||
| CHS 100 II | Dilution E (1+47) 20,0 °C | 100 | 9:00 | Kodak — 30 s zu Beginn, dann 5 s alle 30 s | ||
| CHS 100 II | Dilution B (1+31) 20,0 °C | 100 | 5:30 | Kodak — 30 s zu Beginn, dann 5 s alle 30 s | ||
| CHS 100 II | Dilution D (1+39) 20,0 °C | 100 | 7:00 | Kodak — 30 s zu Beginn, dann 5 s alle 30 s | ||
| CHS 100 II | Dilution E (1+47) 20,0 °C | 100 | 9:00 | Kodak — 30 s zu Beginn, dann 5 s alle 30 s | ||
| Pancro 400 | Dilution B (1+31) 20,0 °C | 400 | 9:00 | — | ||
| Pancro 400 | Dilution B (1+31) 21,0 °C | 400 | 8:20 | — | ||
| Pancro 400 | Dilution B (1+31) 22,0 °C | 400 | 7:40 | — | ||
| Pancro 400 | Dilution B (1+31) 24,0 °C | 400 | 6:30 | — | ||
| 'P' | Dilution A (1+15) 20,0 °C | 100 | 4:30 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 400 Push um 2 Blenden | 11:30 | — | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 400 Push um 2 Blenden | 10:15 | — | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 400 Push um 2 Blenden | 9:15 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 400 Push um 2 Blenden | 7:45 | — | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 400 Push um 2 Blenden | 10:15 | — | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 400 Push um 2 Blenden | 9:15 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 400 Push um 2 Blenden | 7:45 | — | ||
| Fomapan 400 Action | Dilution B (1+31) 20,0 °C | 400 | 6:30 | — | ||
| Retropan 320 Soft | Dilution B (1+31) 20,0 °C | 320 | 7:00 | — | ||
| Retropan 320 Soft | Dilution B (1+31) 20,0 °C | 640 Push um 1 Blende | 11:00 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 18,0 °C | 400 | 6:00 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 20,0 °C | 400 | 5:00 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 22,0 °C | 400 | 4:15 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 24,0 °C | 400 | 3:30 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 26,0 °C | 400 | 3:00 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 18,0 °C | 800 Push um 1 Blende | 8:30 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 20,0 °C | 800 Push um 1 Blende | 7:15 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 22,0 °C | 800 Push um 1 Blende | 6:00 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 24,0 °C | 800 Push um 1 Blende | 5:00 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 26,0 °C | 800 Push um 1 Blende | 4:15 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 18,0 °C | 1600 Push um 2 Blenden | 14:30 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 20,0 °C | 1600 Push um 2 Blenden | 12:00 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 22,0 °C | 1600 Push um 2 Blenden | 10:00 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 24,0 °C | 1600 Push um 2 Blenden | 8:15 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 26,0 °C | 1600 Push um 2 Blenden | 7:00 | — | ||
| 'Y' | Dilution A (1+15) 20,0 °C | 100 | 4:30 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 18,0 °C | 400 | 6:15 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 20,0 °C | 400 | 5:15 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 22,0 °C | 400 | 4:30 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 24,0 °C | 400 | 3:45 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 26,0 °C | 400 | 3:15 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 18,0 °C | 800 Push um 1 Blende | 9:00 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 20,0 °C | 800 Push um 1 Blende | 7:30 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 22,0 °C | 800 Push um 1 Blende | 6:15 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 24,0 °C | 800 Push um 1 Blende | 5:15 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 26,0 °C | 800 Push um 1 Blende | 4:30 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 18,0 °C | 1600 Push um 2 Blenden | 14:30 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 20,0 °C | 1600 Push um 2 Blenden | 12:00 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 22,0 °C | 1600 Push um 2 Blenden | 10:00 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 24,0 °C | 1600 Push um 2 Blenden | 8:30 | — | ||
| Neopan 400 Professional | Dilution B (1+31) 26,0 °C | 1600 Push um 2 Blenden | 7:15 | — | ||
| 'V' | Dilution A (1+15) 20,0 °C | 100 | 4:30 | — | ||
| Neopan 1600 Professional | Dilution B (1+31) 18,0 °C | 800 Pull um 1 Blende | 5:30 | — | ||
| Neopan 1600 Professional | Dilution B (1+31) 20,0 °C | 800 Pull um 1 Blende | 4:45 | — | ||
| Neopan 1600 Professional | Dilution B (1+31) 22,0 °C | 800 Pull um 1 Blende | 4:00 | — | ||
| Neopan 1600 Professional | Dilution B (1+31) 24,0 °C | 800 Pull um 1 Blende | 3:30 | — | ||
| Neopan 1600 Professional | Dilution B (1+31) 18,0 °C | 1600 | 8:15 | — | ||
| Neopan 1600 Professional | Dilution B (1+31) 20,0 °C | 1600 | 7:00 | — | ||
| Neopan 1600 Professional | Dilution B (1+31) 22,0 °C | 1600 | 5:45 | — | ||
| Neopan 1600 Professional | Dilution B (1+31) 24,0 °C | 1600 | 5:00 | — | ||
| Neopan 1600 Professional | Dilution B (1+31) 26,0 °C | 1600 | 4:15 | — | ||
| Pan 100 | Dilution A (1+15) 20,0 °C | 100 | 4:00 | Ilford — 4 Kippungen alle 60 s | ||
| Pan 100 | Dilution A (1+15) 20,0 °C | 200 Push um 1 Blende | 5:00 | Ilford — 4 Kippungen alle 60 s | ||
| Pan 100 | Dilution B (1+31) 20,0 °C | 50 Pull um 1 Blende | 6:00 | Ilford — 4 Kippungen alle 60 s | ||
| Pan 100 | Dilution B (1+31) 20,0 °C | 100 | 8:00 | Ilford — 4 Kippungen alle 60 s | ||
| Pan 100 | Dilution B (1+31) 20,0 °C | 200 Push um 1 Blende | 9:00 | Ilford — 4 Kippungen alle 60 s | ||
| Pan 400 | Dilution A (1+15) 20,0 °C | 400 | 3:00 | Ilford — 4 Kippungen alle 60 s | ||
| Pan 400 | Dilution A (1+15) 20,0 °C | 800 Push um 1 Blende | 5:00 | Ilford — 4 Kippungen alle 60 s | ||
| Pan 400 | Dilution A (1+15) 20,0 °C | 1600 Push um 2 Blenden | 7:00 | Ilford — 4 Kippungen alle 60 s | ||
| Pan 400 | Dilution B (1+31) 20,0 °C | 400 | 6:00 | Ilford — 4 Kippungen alle 60 s | ||
| Pan 400 | Dilution B (1+31) 20,0 °C | 800 Push um 1 Blende | 9:00 | Ilford — 4 Kippungen alle 60 s | ||
| Pan 400 | Dilution B (1+31) 20,0 °C | 1600 Push um 2 Blenden | 14:00 | Ilford — 4 Kippungen alle 60 s | ||
| Lady Grey 400 | Dilution B (1+31) 20,0 °C | 400 | 5:30 | — | ||
| Earl Grey | Dilution B (1+31) 20,0 °C | 100 | 6:30 | — | ||
| Berlin 400 | Dilution B (1+31) 20,0 °C | 400 | 8:07 | — | ||
| Fantome Kino | Dilution B (1+31) 20,0 °C | 8 | 7:00 | — | ||
| Babylon Kino | Dilution B (1+31) 20,0 °C | 13 | 8:30 | — | ||
| Orca | Dilution B (1+31) 20,0 °C | 100 | 8:07 | — | ||
| Agent Shadow | Dilution B (1+31) 20,0 °C | 400 | 5:00 | — | ||
| Agent Shadow | Dilution E (1+47) 20,0 °C | 400 | 8:00 | — | ||
| Agent Shadow | Dilution E (1+47) 20,0 °C | 800 Push um 1 Blende | 13:00 | — | ||
| P30 | Dilution H (1+63) 20,0 °C | 80 | 12:00 | — | ||
| P30 | Dilution B (1+31) 20,0 °C | 80 | 5:00 | — | ||
| 'F' | Dilution A (1+15) 20,0 °C | 100 | 4:30 | — | ||
| 'K' | Dilution B (1+31) 24,0 °C | 100 | 5:00 | — | ||
| WolfMan | Dilution H (1+63) 20,0 °C | 100 | 12:00 | — | ||
| S25 | Dilution F (1+79) 20,0 °C | 25 | 10:00 | — | ||
| U200 | Dilution B (1+31) 20,0 °C | 200 | 4:30 | — | ||
| U400 | Dilution B (1+31) 20,0 °C | 400 | 5:00 | — | ||
| WolfMan | Dilution B (1+31) 20,0 °C | 100 | 6:00 | — | ||
| WolfMan | Dilution H (1+63) 20,0 °C | 100 | 12:00 | — | ||
| WolfMan | Dilution B (1+31) 20,0 °C | 100 | 6:00 | — | ||
| Frankenstein | Dilution B (1+31) 20,0 °C | 200 | 4:00 | — | ||
| Frankenstein | Dilution H (1+63) 20,0 °C | 200 | 9:00 | — | ||
| Frankenstein | Dilution B (1+31) 20,0 °C | 200 | 4:00 | — | ||
| Frankenstein | Dilution H (1+63) 20,0 °C | 200 | 9:00 | — | ||
| Frankenstein | Dilution B (1+31) 20,0 °C | 200 | 4:00 | — | ||
| Frankenstein | Dilution H (1+63) 20,0 °C | 200 | 9:00 | — | ||
| Eastman Kodak Hi-Fi 2374 | Dilution H (1+63) 20,0 °C | 50 | 7:30 | — | ||
| Eastman Kodak Hi-Fi 2374 | Dilution H (1+63) 20,0 °C | 100 Push um 1 Blende | 8:30 | — | ||
| BW IR | Dilution B (1+31) 20,0 °C | 200 | 7:00 | — | ||
| Sonic 25 BW Film | Dilution H (1+63) 20,0 °C | 25 | 11:00 | — | ||
| Xtreme 100 | Dilution B (1+31) 20,0 °C | 100 | 8:30 | — | ||
| Xtreme 400 | Dilution B (1+31) 20,0 °C | 400 | 5:00 | — | ||
| X FILM 320 Pro | 1+49 20,0 °C | 200 Pull um 0,75 Blenden | 10:30 | — | ||
| T-Max 100 | Dilution B (1+31) 18,0 °C | 100 | 7:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 100 | 6:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 100 | 6:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 100 | 5:15 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 100 | 4:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 18,0 °C | 100 | 7:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 100 | 6:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 100 | 6:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 100 | 5:15 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 100 | 4:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 18,0 °C | 100 | 7:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 100 | 6:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 100 | 6:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 100 | 5:15 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 100 | 4:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| T-Max 100 | Dilution B (1+31) 18,0 °C | 100 | 7:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 100 | 5:45 | — | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 100 | 5:15 | — | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 100 | 4:45 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 100 | 4:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 200 Push um 1 Blende | 5:45 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 200 Push um 1 Blende | 4:00 | — | ||
| T-Max 100 | Dilution B (1+31) 18,0 °C | 100 | 7:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 100 | 5:45 | — | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 100 | 5:15 | — | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 100 | 4:45 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 100 | 4:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 200 Push um 1 Blende | 5:45 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 200 Push um 1 Blende | 4:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 400 Push um 2 Blenden | 11:30 | — | ||
| T-Max 100 | Dilution B (1+31) 18,0 °C | 100 | 7:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 100 | 5:45 | — | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 100 | 5:15 | — | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 100 | 4:45 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 100 | 4:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 200 Push um 1 Blende | 5:45 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 200 Push um 1 Blende | 4:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 400 Push um 2 Blenden | 11:30 | — | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 400 Push um 2 Blenden | 10:15 | — | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 400 Push um 2 Blenden | 9:15 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 400 Push um 2 Blenden | 7:45 | — | ||
| T-Max 100 | Dilution B (1+31) 18,0 °C | 100 | 6:30 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 100 | 6:00 | — | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 100 | 5:30 | — | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 100 | 5:00 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 100 | 4:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 200 Push um 1 Blende | 6:00 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 200 Push um 1 Blende | 4:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 400 Push um 2 Blenden | 11:30 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 400 Push um 2 Blenden | 7:45 | — | ||
| T-Max 100 | Dilution B (1+31) 18,0 °C | 100 | 6:30 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 100 | 6:00 | — | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 100 | 5:30 | — | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 100 | 5:00 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 100 | 4:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 200 Push um 1 Blende | 6:00 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 200 Push um 1 Blende | 4:00 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 400 Push um 2 Blenden | 11:30 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 400 Push um 2 Blenden | 7:45 | — | ||
| T-Max 100 | Dilution B (1+31) 18,0 °C | 100 | 6:15 | — | ||
| T-Max 100 | Dilution B (1+31) 20,0 °C | 100 | 5:30 | — | ||
| T-Max 100 | Dilution B (1+31) 21,0 °C | 100 | 4:45 | — | ||
| T-Max 100 | Dilution B (1+31) 22,0 °C | 100 | 4:30 | — | ||
| T-Max 100 | Dilution B (1+31) 24,0 °C | 100 | 3:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 20,0 °C | 400 Pull um 3 Blenden | 7:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 21,0 °C | 400 Pull um 3 Blenden | 6:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 22,0 °C | 400 Pull um 3 Blenden | 5:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 24,0 °C | 400 Pull um 3 Blenden | 5:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 27,0 °C | 400 Pull um 3 Blenden | 4:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 29,0 °C | 400 Pull um 3 Blenden | 3:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 20,0 °C | 800 Pull um 2 Blenden | 8:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 21,0 °C | 800 Pull um 2 Blenden | 7:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 22,0 °C | 800 Pull um 2 Blenden | 6:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 24,0 °C | 800 Pull um 2 Blenden | 5:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 27,0 °C | 800 Pull um 2 Blenden | 4:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 29,0 °C | 800 Pull um 2 Blenden | 4:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 20,0 °C | 1600 Pull um 1 Blende | 9:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 21,0 °C | 1600 Pull um 1 Blende | 8:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 22,0 °C | 1600 Pull um 1 Blende | 6:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 24,0 °C | 1600 Pull um 1 Blende | 6:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 27,0 °C | 1600 Pull um 1 Blende | 5:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 29,0 °C | 1600 Pull um 1 Blende | 4:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 20,0 °C | 3200 | 10:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 21,0 °C | 3200 | 9:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 22,0 °C | 3200 | 7:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 24,0 °C | 3200 | 7:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 27,0 °C | 3200 | 6:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 29,0 °C | 3200 | 5:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 20,0 °C | 6400 Push um 1 Blende | 12:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 21,0 °C | 6400 Push um 1 Blende | 10:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 22,0 °C | 6400 Push um 1 Blende | 8:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 24,0 °C | 6400 Push um 1 Blende | 8:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 27,0 °C | 6400 Push um 1 Blende | 6:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 29,0 °C | 6400 Push um 1 Blende | 5:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 20,0 °C | 400 Pull um 3 Blenden | 7:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 21,0 °C | 400 Pull um 3 Blenden | 6:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 22,0 °C | 400 Pull um 3 Blenden | 5:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 24,0 °C | 400 Pull um 3 Blenden | 5:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 27,0 °C | 400 Pull um 3 Blenden | 4:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 29,0 °C | 400 Pull um 3 Blenden | 3:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 20,0 °C | 800 Pull um 2 Blenden | 8:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 21,0 °C | 800 Pull um 2 Blenden | 7:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 22,0 °C | 800 Pull um 2 Blenden | 6:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 24,0 °C | 800 Pull um 2 Blenden | 5:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 27,0 °C | 800 Pull um 2 Blenden | 4:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 29,0 °C | 800 Pull um 2 Blenden | 4:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 20,0 °C | 1600 Pull um 1 Blende | 9:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 21,0 °C | 1600 Pull um 1 Blende | 8:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 22,0 °C | 1600 Pull um 1 Blende | 6:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 24,0 °C | 1600 Pull um 1 Blende | 6:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 27,0 °C | 1600 Pull um 1 Blende | 5:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 29,0 °C | 1600 Pull um 1 Blende | 4:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 20,0 °C | 3200 | 10:30 | — | ||
| T-Max P3200 | Dilution B (1+31) 21,0 °C | 3200 | 9:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 22,0 °C | 3200 | 7:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 24,0 °C | 3200 | 7:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 27,0 °C | 3200 | 6:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 29,0 °C | 3200 | 5:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 20,0 °C | 6400 Push um 1 Blende | 12:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 21,0 °C | 6400 Push um 1 Blende | 10:15 | — | ||
| T-Max P3200 | Dilution B (1+31) 22,0 °C | 6400 Push um 1 Blende | 8:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 24,0 °C | 6400 Push um 1 Blende | 8:00 | — | ||
| T-Max P3200 | Dilution B (1+31) 27,0 °C | 6400 Push um 1 Blende | 6:45 | — | ||
| T-Max P3200 | Dilution B (1+31) 29,0 °C | 6400 Push um 1 Blende | 5:45 | — | ||
| Tri-X | Dilution B (1+31) 18,0 °C | 320 | 6:15 | Kodak — großer Tank, Intervalle von 1 min | ||
| Tri-X | Dilution B (1+31) 20,0 °C | 320 | 5:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| Tri-X | Dilution B (1+31) 21,0 °C | 320 | 5:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| Tri-X | Dilution B (1+31) 22,0 °C | 320 | 4:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| Tri-X | Dilution B (1+31) 24,0 °C | 320 | 4:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| Tri-X | Dilution B (1+31) 18,0 °C | 320 | 4:45 | Kodak — großer Tank, Intervalle von 1 min | ||
| Tri-X | Dilution B (1+31) 20,0 °C | 320 | 4:15 | Kodak — großer Tank, Intervalle von 1 min | ||
| Tri-X | Dilution B (1+31) 21,0 °C | 320 | 4:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| Tri-X | Dilution B (1+31) 22,0 °C | 320 | 3:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| Tri-X | Dilution B (1+31) 24,0 °C | 320 | 3:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| Tri-X | Dilution B (1+31) 18,0 °C | 320 | 5:15 | — | ||
| Tri-X | Dilution B (1+31) 20,0 °C | 320 | 4:45 | — | ||
| Tri-X | Dilution B (1+31) 21,0 °C | 320 | 4:15 | — | ||
| Tri-X | Dilution B (1+31) 22,0 °C | 320 | 4:00 | — | ||
| Tri-X | Dilution B (1+31) 24,0 °C | 320 | 3:30 | — | ||
| Tri-X | Dilution B (1+31) 18,0 °C | 320 | 3:15 | — | ||
| Tri-X | Dilution B (1+31) 20,0 °C | 320 | 3:00 | — | ||
| Tri-X | Dilution B (1+31) 21,0 °C | 320 | 2:45 | — | ||
| Tri-X | Dilution B (1+31) 22,0 °C | 320 | 2:30 | — | ||
| Tri-X | Dilution B (1+31) 24,0 °C | 320 | 2:15 | — | ||
| Tri-X | Dilution B (1+31) 18,0 °C | 320 | 5:15 | — | ||
| Tri-X | Dilution B (1+31) 20,0 °C | 320 | 4:45 | — | ||
| Tri-X | Dilution B (1+31) 21,0 °C | 320 | 4:15 | — | ||
| Tri-X | Dilution B (1+31) 22,0 °C | 320 | 4:00 | — | ||
| Tri-X | Dilution B (1+31) 24,0 °C | 320 | 3:30 | — | ||
| Tri-X | Dilution B (1+31) 18,0 °C | 320 | 3:45 | — | ||
| Tri-X | Dilution B (1+31) 20,0 °C | 320 | 3:15 | — | ||
| Tri-X | Dilution B (1+31) 21,0 °C | 320 | 3:00 | — | ||
| Tri-X | Dilution B (1+31) 22,0 °C | 320 | 2:45 | — | ||
| Tri-X | Dilution B (1+31) 24,0 °C | 320 | 2:30 | — | ||
| Plus-X Pan | Dilution B (1+31) 18,0 °C | 125 | 4:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| Plus-X Pan | Dilution B (1+31) 20,0 °C | 125 | 3:45 | Kodak — großer Tank, Intervalle von 1 min | ||
| Plus-X Pan | Dilution B (1+31) 21,0 °C | 125 | 3:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| Plus-X Pan | Dilution B (1+31) 22,0 °C | 125 | 3:15 | Kodak — großer Tank, Intervalle von 1 min | ||
| Plus-X Pan | Dilution B (1+31) 24,0 °C | 125 | 2:45 | Kodak — großer Tank, Intervalle von 1 min | ||
| Plus-X Pan | Dilution B (1+31) 18,0 °C | 125 | 4:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| Plus-X Pan | Dilution B (1+31) 20,0 °C | 125 | 3:45 | Kodak — großer Tank, Intervalle von 1 min | ||
| Plus-X Pan | Dilution B (1+31) 21,0 °C | 125 | 3:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| Plus-X Pan | Dilution B (1+31) 22,0 °C | 125 | 3:15 | Kodak — großer Tank, Intervalle von 1 min | ||
| Plus-X Pan | Dilution B (1+31) 24,0 °C | 125 | 2:45 | Kodak — großer Tank, Intervalle von 1 min | ||
| Plus-X Pan | Dilution B (1+31) 18,0 °C | 125 | 4:00 | — | ||
| Plus-X Pan | Dilution B (1+31) 20,0 °C | 125 | 3:30 | — | ||
| Plus-X Pan | Dilution B (1+31) 21,0 °C | 125 | 3:00 | — | ||
| Plus-X Pan | Dilution B (1+31) 22,0 °C | 125 | 2:45 | — | ||
| Plus-X Pan | Dilution B (1+31) 24,0 °C | 125 | 2:30 | — | ||
| Plus-X Pan | Dilution B (1+31) 18,0 °C | 125 | 4:00 | — | ||
| Plus-X Pan | Dilution B (1+31) 20,0 °C | 125 | 3:30 | — | ||
| Plus-X Pan | Dilution B (1+31) 21,0 °C | 125 | 3:00 | — | ||
| Plus-X Pan | Dilution B (1+31) 22,0 °C | 125 | 2:45 | — | ||
| Plus-X Pan | Dilution B (1+31) 24,0 °C | 125 | 2:30 | — | ||
| Plus-X Pan | Dilution B (1+31) 18,0 °C | 125 | 4:00 | — | ||
| Plus-X Pan | Dilution B (1+31) 20,0 °C | 125 | 3:30 | — | ||
| Plus-X Pan | Dilution B (1+31) 21,0 °C | 125 | 3:00 | — | ||
| Plus-X Pan | Dilution B (1+31) 22,0 °C | 125 | 2:45 | — | ||
| Plus-X Pan | Dilution B (1+31) 24,0 °C | 125 | 2:30 | — | ||
| Plus-X Pan | Dilution B (1+31) 18,0 °C | 125 | 4:00 | — | ||
| Plus-X Pan | Dilution B (1+31) 20,0 °C | 125 | 3:30 | — | ||
| Plus-X Pan | Dilution B (1+31) 21,0 °C | 125 | 3:00 | — | ||
| Plus-X Pan | Dilution B (1+31) 22,0 °C | 125 | 2:45 | — | ||
| Plus-X Pan | Dilution B (1+31) 24,0 °C | 125 | 2:30 | — | ||
| Verichrome Pan | Dilution B (1+31) 18,0 °C | 125 Push um 0,75 Blenden | 8:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| Verichrome Pan | Dilution B (1+31) 20,0 °C | 125 Push um 0,75 Blenden | 6:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| Verichrome Pan | Dilution B (1+31) 21,0 °C | 125 Push um 0,75 Blenden | 6:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| Verichrome Pan | Dilution B (1+31) 22,0 °C | 125 Push um 0,75 Blenden | 5:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| Verichrome Pan | Dilution B (1+31) 24,0 °C | 125 Push um 0,75 Blenden | 4:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| Verichrome Pan | Dilution B (1+31) 18,0 °C | 125 Push um 0,75 Blenden | 6:00 | — | ||
| Verichrome Pan | Dilution B (1+31) 20,0 °C | 125 Push um 0,75 Blenden | 5:00 | — | ||
| Verichrome Pan | Dilution B (1+31) 21,0 °C | 125 Push um 0,75 Blenden | 4:30 | — | ||
| Verichrome Pan | Dilution B (1+31) 22,0 °C | 125 Push um 0,75 Blenden | 4:00 | — | ||
| Ektapan | Dilution A (1+15) 18,0 °C | 100 | 4:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| Ektapan | Dilution A (1+15) 20,0 °C | 100 | 3:45 | Kodak — großer Tank, Intervalle von 1 min | ||
| Ektapan | Dilution A (1+15) 21,0 °C | 100 | 3:15 | Kodak — großer Tank, Intervalle von 1 min | ||
| Ektapan | Dilution A (1+15) 22,0 °C | 100 | 3:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| Ektapan | Dilution A (1+15) 24,0 °C | 100 | 2:45 | Kodak — großer Tank, Intervalle von 1 min | ||
| Ektapan | Dilution B (1+31) 18,0 °C | 100 | 7:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| Ektapan | Dilution B (1+31) 20,0 °C | 100 | 6:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| Ektapan | Dilution B (1+31) 21,0 °C | 100 | 5:30 | Kodak — großer Tank, Intervalle von 1 min | ||
| Ektapan | Dilution B (1+31) 22,0 °C | 100 | 5:00 | Kodak — großer Tank, Intervalle von 1 min | ||
| Ektapan | Dilution B (1+31) 24,0 °C | 100 | 4:15 | Kodak — großer Tank, Intervalle von 1 min | ||
| Ektapan | Dilution A (1+15) 18,0 °C | 100 | 3:15 | — | ||
| Ektapan | Dilution A (1+15) 20,0 °C | 100 | 3:00 | — | ||
| Ektapan | Dilution A (1+15) 21,0 °C | 100 | 2:45 | — | ||
| Ektapan | Dilution A (1+15) 22,0 °C | 100 | 2:30 | — | ||
| Ektapan | Dilution A (1+15) 24,0 °C | 100 | 2:15 | — | ||
| Ektapan | Dilution B (1+31) 18,0 °C | 100 | 5:00 | — | ||
| Ektapan | Dilution B (1+31) 20,0 °C | 100 | 4:30 | — | ||
| Ektapan | Dilution B (1+31) 21,0 °C | 100 | 4:15 | — | ||
| Ektapan | Dilution B (1+31) 22,0 °C | 100 | 4:00 | — | ||
| Ektapan | Dilution B (1+31) 24,0 °C | 100 | 3:30 | — | ||
| RPX 25 | Dilution B (1+31) 20,0 °C | 25 | 5:00 | — | ||
| RPX 100 | Dilution B (1+31) 20,0 °C | 100 | 8:00 | — | ||
| RPX 400 | Dilution B (1+31) 20,0 °C | 400 | 6:00 | — | ||
| Retro 80S | Dilution B (1+31) 20,0 °C | 80 | 8:00 | — | ||
| Retro 400S | Dilution B (1+31) 20,0 °C | 400 | 10:00 | — | ||
| SuperPan 200 | Dilution B (1+31) 20,0 °C | 200 | 8:00 | — | ||
| Infrared 400 | Dilution B (1+31) 20,0 °C | 400 | 5:00 | — | ||
| T-Max 400 | Dilution B (1+31) 18,0 °C | 400 | 7:00 | — | ||
| T-Max 400 | Dilution B (1+31) 20,0 °C | 400 | 6:15 | — | ||
| T-Max 400 | Dilution B (1+31) 21,0 °C | 400 | 5:45 | — | ||
| T-Max 400 | Dilution B (1+31) 22,0 °C | 400 | 5:30 | — | ||
| T-Max 400 | Dilution B (1+31) 24,0 °C | 400 | 5:00 | — | ||
| T-Max 400 | Dilution B (1+31) 18,0 °C | 400 | 7:00 | — | ||
| T-Max 400 | Dilution B (1+31) 20,0 °C | 400 | 6:15 | — | ||
| T-Max 400 | Dilution B (1+31) 21,0 °C | 400 | 5:45 | — | ||
| T-Max 400 | Dilution B (1+31) 22,0 °C | 400 | 5:30 | — | ||
| T-Max 400 | Dilution B (1+31) 24,0 °C | 400 | 5:00 | — | ||
| T-Max 400 | Dilution B (1+31) 18,0 °C | 400 | 7:00 | — | ||
| T-Max 400 | Dilution B (1+31) 20,0 °C | 400 | 6:15 | — | ||
| T-Max 400 | Dilution B (1+31) 21,0 °C | 400 | 5:45 | — | ||
| T-Max 400 | Dilution B (1+31) 22,0 °C | 400 | 5:30 | — | ||
| T-Max 400 | Dilution B (1+31) 24,0 °C | 400 | 5:00 | — | ||
| T-Max 400 | Dilution B (1+31) 18,0 °C | 400 | 6:15 | — | ||
| T-Max 400 | Dilution B (1+31) 20,0 °C | 400 | 5:30 | — | ||
| T-Max 400 | Dilution B (1+31) 21,0 °C | 400 | 5:15 | — | ||
| T-Max 400 | Dilution B (1+31) 22,0 °C | 400 | 4:45 | — | ||
| T-Max 400 | Dilution B (1+31) 24,0 °C | 400 | 4:30 | — | ||
| T-Max 400 | Dilution B (1+31) 18,0 °C | 400 | 6:15 | — | ||
| T-Max 400 | Dilution B (1+31) 20,0 °C | 400 | 5:30 | — | ||
| T-Max 400 | Dilution B (1+31) 21,0 °C | 400 | 5:15 | — | ||
| T-Max 400 | Dilution B (1+31) 22,0 °C | 400 | 4:45 | — | ||
| T-Max 400 | Dilution B (1+31) 24,0 °C | 400 | 4:30 | — | ||
| T-Max 400 | Dilution B (1+31) 18,0 °C | 400 | 6:15 | — | ||
| T-Max 400 | Dilution B (1+31) 20,0 °C | 400 | 5:30 | — | ||
| T-Max 400 | Dilution B (1+31) 21,0 °C | 400 | 5:15 | — | ||
| T-Max 400 | Dilution B (1+31) 22,0 °C | 400 | 4:45 | — | ||
| T-Max 400 | Dilution B (1+31) 24,0 °C | 400 | 4:30 | — | ||
| T-Max 400 | Dilution B (1+31) 18,0 °C | 400 | 6:15 | — | ||
| T-Max 400 | Dilution B (1+31) 20,0 °C | 400 | 5:30 | — | ||
| T-Max 400 | Dilution B (1+31) 21,0 °C | 400 | 5:15 | — | ||
| T-Max 400 | Dilution B (1+31) 22,0 °C | 400 | 4:45 | — | ||
| T-Max 400 | Dilution B (1+31) 24,0 °C | 400 | 4:30 | — | ||
| T-Max 400 | Dilution B (1+31) 18,0 °C | 400 | 6:15 | — | ||
| T-Max 400 | Dilution B (1+31) 20,0 °C | 400 | 5:30 | — | ||
| T-Max 400 | Dilution B (1+31) 21,0 °C | 400 | 5:15 | — | ||
| T-Max 400 | Dilution B (1+31) 22,0 °C | 400 | 4:45 | — | ||
| T-Max 400 | Dilution B (1+31) 24,0 °C | 400 | 4:30 | — | ||
| T-Max 400 | Dilution B (1+31) 24,0 °C | 400 | 4:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 18,0 °C | 400 | 5:00 | — | ||
| Tri-X 400 | Dilution B (1+31) 20,0 °C | 400 | 4:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 21,0 °C | 400 | 4:00 | — | ||
| Tri-X 400 | Dilution B (1+31) 22,0 °C | 400 | 3:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 24,0 °C | 400 | 3:00 | — | ||
| Tri-X 400 | Dilution B (1+31) 18,0 °C | 400 | 5:00 | — | ||
| Tri-X 400 | Dilution B (1+31) 20,0 °C | 400 | 4:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 21,0 °C | 400 | 4:00 | — | ||
| Tri-X 400 | Dilution B (1+31) 22,0 °C | 400 | 3:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 24,0 °C | 400 | 3:00 | — | ||
| Tri-X 400 | Dilution B (1+31) 18,0 °C | 400 | 4:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 20,0 °C | 400 | 3:45 | — | ||
| Tri-X 400 | Dilution B (1+31) 21,0 °C | 400 | 3:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 22,0 °C | 400 | 3:00 | — | ||
| Tri-X 400 | Dilution B (1+31) 24,0 °C | 400 | 2:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 18,0 °C | 400 | 4:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 20,0 °C | 400 | 3:45 | — | ||
| Tri-X 400 | Dilution B (1+31) 21,0 °C | 400 | 3:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 22,0 °C | 400 | 3:00 | — | ||
| Tri-X 400 | Dilution B (1+31) 24,0 °C | 400 | 2:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 18,0 °C | 400 | 4:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 20,0 °C | 400 | 3:45 | — | ||
| Tri-X 400 | Dilution B (1+31) 21,0 °C | 400 | 3:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 22,0 °C | 400 | 3:00 | — | ||
| Tri-X 400 | Dilution B (1+31) 24,0 °C | 400 | 2:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 18,0 °C | 400 | 4:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 20,0 °C | 400 | 3:45 | — | ||
| Tri-X 400 | Dilution B (1+31) 21,0 °C | 400 | 3:30 | — | ||
| Tri-X 400 | Dilution B (1+31) 22,0 °C | 400 | 3:00 | — | ||
| Tri-X 400 | Dilution B (1+31) 24,0 °C | 400 | 2:30 | — |
Wiederverwendung
Geprüft am 21. Oktober 2026
Kodak sagt, Kodak HC-110 lasse sich für mehr als einen Film verwenden. Er kann auch regeneriert werden.
- Dilution A (1+15) darf wiederverwendet werden
- Dilution B (1+31) darf wiederverwendet werden
- Dilution E (1+47) darf wiederverwendet werden
- Dilution D (1+39) darf wiederverwendet werden
- Dilution F (1+79) einmal verwenden
Der Hersteller veröffentlicht keine Regel zur Verlängerung der Zeit, daher nimmt der Rechner keine Korrektur vor.
Kapazität laut Hersteller: Tank, without replenishment, per gallon (8x10-inch sheets or equivalent): A 40, B 20, C 30, D 15, E 10, F not recommended.
It can be used for replenished and non-replenished systems. Use KODAK PROFESSIONAL HC-110 Developer Replenisher to replenish. ... Discard the developer after processing the number of sheets (or equivalent) listed below. ... Replenish tank solutions ... discard the tank solution when you have: Replenished the solution for two weeks; Added an amount of replenisher that equals the original volume of the working solution; or Processed fifty 20.3 x 25.4 cm sheets per litre (two hundred 8 x 10-inch sheets [or equivalent] per gallon) of developer.
Verdünnungen
- Dilution A (1+15) 1 + 15 Wasser
- Dilution B (1+31) 1 + 31 Wasser
- Dilution E (1+47) 1 + 47 Wasser
- Dilution H (1+63) 1 + 63 Wasser
- Dilution D (1+39) 1 + 39 Wasser
- Dilution F (1+79) 1 + 79 Wasser
- 1+49 1 + 49 Wasser
Link zu dieser Seite
Spezifikation
- Typ
- S/W-Entwickler
- Form
- Flüssigkonzentrat
- Kapazität Filme pro Liter
- —
- Haltbarkeit, ungeöffnet
- —
- Haltbarkeit, geöffnet
- —
Ein Strich bedeutet, dass der Wert nicht aus dem Datenblatt des Herstellers abgelesen wurde. Eine Vermutung hier würde stillschweigend falsche Antworten liefern.
Zeit vorschlagen oder Fehler melden
Kennen Sie eine Zeit für HC-110, die hier fehlt, oder haben Sie eine falsche entdeckt? Teilen Sie sie uns mit Quelle mit, und ein Kurator prüft sie.
- Nur Quellen. Wir veröffentlichen eine Zeit nur, wenn sie aus einer Primärquelle abgelesen wurde: dem Datenblatt oder der Tabelle des Herstellers. Ein Link dorthin ermöglicht uns, Ihre zu prüfen.
- Nichts geht von selbst online. Jede Meldung wird von einer Person gelesen, bevor sich etwas auf der Seite ändert.
- Kein Konto nötig. Name und E-Mail-Adresse sind optional und dienen nur dazu, Ihnen zu antworten.
0 Bewertungen
Von Fotografen unter ihrem eigenen Profil geschrieben – so sehen Sie, was sie fotografieren, bevor Sie abwägen, was sie sagen.