B&W developer Liquid concentrate In production Reusable at some dilutions Replenishable

Development times

Clear

Showing 2 of 86 published times.

Film Dilution EI Time Source
Delta 400 Professional 1+31 20.0 °C 200 pull 1 stop 5:00
Verified Datasheet Report
Delta 400 Professional 1+31 24.0 °C 200 pull 1 stop 4:00
Verified Datasheet Report

Reuse

Checked 21 October 2026

Ilford says whether Ilford Ilfotec HC may be reused depends on how it is used. It can also be replenished.

  • 1+11 use once
  • 1+15 may be reused
  • 1+31 may be reused

1+15: +10 % development time for each successive film in a litre (N, N+10 %, N+20 % ...), up to N+90 % for film 10.

1+31: +10 % development time for each successive film in a litre (N, N+10 %, N+20 % ...), up to N+40 % for film 5.

Capacity, as the maker states it: Reused working solution: 10 films per litre at 1+15, 5 films per litre at 1+31.

ILFOTEC HC 1+15 and 1+31 working strength developer in spiral tanks without replenishment to process either a number of films individually or multiple films in batches. ... The table below gives the number of 135/36 or 120 roll films a litre of working strength ILFOTEC HC can process provided that the developer is reused. ... ILFOTEC HC 1+15: 10 films/litre; ILFOTEC HC 1+31: 5 films/litre. ... We do not recommend reusing diluted developers, 1+47, always use fresh solutions on each occasion. ... Do not use ILFOTEC HC developer as replenisher.

ILFORD ILFOTEC HC Technical Information (Harman, June 2010, 13 pp.) ↗

Dilutions

  • 1+11 1 + 11 water
  • 1+15 1 + 15 water
  • 1+31 1 + 31 water

Link to this page

Specification

Type
B&W developer
Form
Liquid concentrate
Capacity rolls per litre
—
Shelf life, unopened
—
Shelf life, opened
—

A dash means the figure has not been read off the maker’s sheet. A guess here would produce wrong answers silently.

Help keep it right Form R-1

Suggest a time or report a mistake

Know a time for Ilfotec HC that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.

0 reviews

Written by photographers, under their own profile — so you can see what they shoot before you weigh what they say.