Skip to content

Development times

Kodak T-Max 100 in Kodak XTOL

132 published times at stock, 1+1, rated at EI 100–800, 18.0–24.0 °C. Each one is linked to the datasheet or chart it was read from.

Open in the calculator

At box speed

8:00

Open in the calculator ›

Speed

EI 100

Dilution

stock

Temperature

18.0 °C

Every published time

Showing 132 of 132 published times.

Developer Dilution EI Temp Time Agitation Source
XTOL stock 100 18.0 °C 8:00 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 8:30 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 8:30 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 8:45 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 8:45 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 8:45 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 9:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 18.0 °C 9:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 18.0 °C 9:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 10:30 —
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 11:30 —
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 11:30 —
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 11:45 —
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 11:45 —
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 11:45 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 6:45 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 7:30 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 7:30 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 20.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 20.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:00 —
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:30 —
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:30 —
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:45 —
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:45 —
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:45 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:00 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 21.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 21.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 8:00 —
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 8:30 —
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 8:30 —
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 8:45 —
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 8:45 —
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 9:00 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 5:15 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 5:45 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 5:45 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 5:45 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 6:00 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 6:00 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 22.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 22.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 100 22.0 °C 7:00 —
Verified Datasheet Report
XTOL 1+1 100 22.0 °C 7:45 —
Verified Datasheet Report
XTOL 1+1 100 22.0 °C 7:45 —
Verified Datasheet Report
XTOL 1+1 100 22.0 °C 8:30 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 4:30 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:00 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:00 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:00 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:00 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:00 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 6:00 —
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 6:30 —
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 6:30 —
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 6:45 —
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 6:45 —
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 7:45 —
Verified Datasheet Report
XTOL stock 200 push 1 stop 20.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 200 push 1 stop 20.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 200 push 1 stop 20.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 200 push 1 stop 20.0 °C 7:30 —
Verified Datasheet Report
XTOL stock 200 push 1 stop 20.0 °C 7:30 —
Verified Datasheet Report
XTOL 1+1 200 push 1 stop 20.0 °C 9:30 —
Verified Datasheet Report
XTOL 1+1 200 push 1 stop 20.0 °C 9:30 —
Verified Datasheet Report
XTOL 1+1 200 push 1 stop 20.0 °C 9:45 —
Verified Datasheet Report
XTOL 1+1 200 push 1 stop 20.0 °C 9:45 —
Verified Datasheet Report
XTOL 1+1 200 push 1 stop 20.0 °C 9:45 —
Verified Datasheet Report
XTOL stock 200 push 1 stop 24.0 °C 5:00 —
Verified Datasheet Report
XTOL stock 200 push 1 stop 24.0 °C 5:00 —
Verified Datasheet Report
XTOL stock 200 push 1 stop 24.0 °C 5:00 —
Verified Datasheet Report
XTOL stock 200 push 1 stop 24.0 °C 5:00 —
Verified Datasheet Report
XTOL stock 200 push 1 stop 24.0 °C 5:00 —
Verified Datasheet Report
XTOL 1+1 200 push 1 stop 24.0 °C 6:30 —
Verified Datasheet Report
XTOL 1+1 200 push 1 stop 24.0 °C 6:30 —
Verified Datasheet Report
XTOL 1+1 200 push 1 stop 24.0 °C 7:45 —
Verified Datasheet Report
XTOL 1+1 200 push 1 stop 24.0 °C 7:45 —
Verified Datasheet Report
XTOL 1+1 200 push 1 stop 24.0 °C 7:45 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 20.0 °C 9:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 20.0 °C 9:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 20.0 °C 9:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 20.0 °C 9:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 20.0 °C 9:30 —
Verified Datasheet Report
XTOL 1+1 400 push 2 stops 20.0 °C 12:15 —
Verified Datasheet Report
XTOL 1+1 400 push 2 stops 20.0 °C 12:15 —
Verified Datasheet Report
XTOL 1+1 400 push 2 stops 20.0 °C 12:15 —
Verified Datasheet Report
XTOL 1+1 400 push 2 stops 20.0 °C 12:15 —
Verified Datasheet Report
XTOL 1+1 400 push 2 stops 20.0 °C 12:15 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 21.0 °C 8:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 21.0 °C 8:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 21.0 °C 8:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 22.0 °C 7:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 22.0 °C 7:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 22.0 °C 7:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 24.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 24.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 24.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 24.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 24.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 400 push 2 stops 24.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 400 push 2 stops 24.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 400 push 2 stops 24.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 400 push 2 stops 24.0 °C 8:15 —
Verified Datasheet Report
XTOL 1+1 400 push 2 stops 24.0 °C 8:15 —
Verified Datasheet Report
XTOL 1+1 400 push 2 stops 24.0 °C 8:15 —
Verified Datasheet Report
XTOL 1+1 400 push 2 stops 24.0 °C 8:15 —
Verified Datasheet Report
XTOL 1+1 400 push 2 stops 24.0 °C 8:15 —
Verified Datasheet Report
XTOL stock 800 push 3 stops 24.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 800 push 3 stops 24.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 800 push 3 stops 24.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 800 push 3 stops 24.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 800 push 3 stops 24.0 °C 7:15 —
Verified Datasheet Report
XTOL 1+1 800 push 3 stops 24.0 °C 9:00 —
Verified Datasheet Report
XTOL 1+1 800 push 3 stops 24.0 °C 9:00 —
Verified Datasheet Report
XTOL 1+1 800 push 3 stops 24.0 °C 9:00 —
Verified Datasheet Report
XTOL 1+1 800 push 3 stops 24.0 °C 9:00 —
Verified Datasheet Report
XTOL 1+1 800 push 3 stops 24.0 °C 9:00 —
Verified Datasheet Report

Help keep it right

Suggest a time or report a mistake.

Know a time for T-Max 100 in XTOL that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.