Development times
SPUR DSX in SPUR Dokuspeed SL-N
8 published times at 7.5 ml A + 7.5 ml B to 250 ml, 10 ml A + 5 ml B to 250 ml, 20 ml A + 15 ml B to 500 ml, rated at EI 12–100, 20.0–28.0 °C. Each one is linked to the datasheet or chart it was read from.
Open in the calculator
Every published time
| Developer | Dilution | EI | Temp | Time | Agitation | Source |
|---|---|---|---|---|---|---|
| Dokuspeed SL-N | 7.5 ml A + 7.5 ml B to 250 ml | 12 pull 1.5 stops | 20.0 °C | 8:00 | — | |
| Dokuspeed SL-N | 7.5 ml A + 7.5 ml B to 250 ml | 12 pull 1.5 stops | 20.0 °C | 9:00 | — | |
| Dokuspeed SL-N | 10 ml A + 5 ml B to 250 ml | 25 pull 0.25 stops | 20.0 °C | 10:30 | — | |
| Dokuspeed SL-N | 10 ml A + 5 ml B to 250 ml | 25 pull 0.25 stops | 22.0 °C | 11:30 | — | |
| Dokuspeed SL-N | 10 ml A + 5 ml B to 250 ml | 50 push 0.75 stops | 26.0 °C | 10:00 | — | |
| Dokuspeed SL-N | 10 ml A + 5 ml B to 250 ml | 50 push 0.75 stops | 26.0 °C | 10:00 | — | |
| Dokuspeed SL-N | 20 ml A + 15 ml B to 500 ml | 80 push 1.25 stops | 28.0 °C | 12:00 | — | |
| Dokuspeed SL-N | 10 ml A + 5 ml B to 250 ml | 100 push 1.75 stops | 28.0 °C | 12:00 | — |
About the film
About the developer
Help keep it right
Suggest a time or report a mistake.
Know a time for DSX in Dokuspeed SL-N that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.
- Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
- Nothing goes up by itself. Every report is read by a person before anything on the page changes.
- No account needed. Your name and email are optional, and only to reply to you.