B&W developer Liquid concentrate In production Reusable

Development times

Showing 73 of 73 published times.

Film Dilution EI Temp Time Agitation Source
Berlin 400 1+4 400 20.0 °C 8:00 —
Unverified Datasheet Report
Ilford Delta 100 Pro 1+4 100 20.0 °C 10:30 —
Unverified Datasheet Report
Ilford Delta 100 Pro 1+4 100 20.0 °C 10:30 —
Unverified Datasheet Report
Pan F Plus 1+4 25 pull 1 stop 20.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan F Plus 1+4 50 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus 1+4 50 pull 1.25 stops 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus 1+4 125 20.0 °C 10:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus 1+4 200 push 0.75 stops 20.0 °C 12:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro 1+4 50 pull 1 stop 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro 1+4 100 20.0 °C 10:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro 1+4 200 push 1 stop 20.0 °C 12:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+4 400 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+4 800 push 1 stop 20.0 °C 10:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+4 1600 push 2 stops 20.0 °C 13:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+4 3200 push 3 stops 20.0 °C 20:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 1+4 200 20.0 °C 10:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 1+4 400 push 1 stop 20.0 °C 14:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 200 pull 1 stop 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 400 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 500 push 0.25 stops 20.0 °C 9:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 800 push 1 stop 20.0 °C 10:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 1600 push 2 stops 20.0 °C 13:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 3200 push 3 stops 20.0 °C 18:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 200 pull 1 stop 24.0 °C 4:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 400 24.0 °C 5:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 500 push 0.25 stops 24.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 800 push 1 stop 24.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 1600 push 2 stops 24.0 °C 9:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 3200 push 3 stops 24.0 °C 13:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+4 400 pull 3 stops 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+4 800 pull 2 stops 20.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+4 1600 pull 1 stop 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+4 3200 20.0 °C 9:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+4 6400 push 1 stop 20.0 °C 12:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+4 12500 push 2 stops 20.0 °C 17:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+4 800 pull 2 stops 24.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+4 1600 pull 1 stop 24.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+4 3200 24.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+4 6400 push 1 stop 24.0 °C 9:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+4 12500 push 2 stops 24.0 °C 12:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
HR-50 1+4 50 20.0 °C 7:30 —
Verified Datasheet Report
CHS 100 II 1+4 100 20.0 °C 7:00 —
Verified Datasheet Report
CHS 100 II 1+4 100 20.0 °C 7:00 —
Verified Datasheet Report
Pan 200 1+4 100 pull 1 stop 20.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 200 1+4 200 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 200 1+4 400 push 1 stop 20.0 °C 12:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ortho Plus 1+4 80 20.0 °C 10:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 100 1+4 50 pull 1 stop 20.0 °C 7:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 1+4 100 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 1+4 200 push 1 stop 20.0 °C 11:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+4 200 pull 1 stop 20.0 °C 7:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+4 400 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+4 800 push 1 stop 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+4 1600 push 2 stops 20.0 °C 12:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+4 3200 push 3 stops 20.0 °C 18:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 1+4 50 pull 1 stop 20.0 °C 8:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 100 1+4 100 20.0 °C 10:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 100 1+4 200 push 1 stop 20.0 °C 12:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 400 1+4 400 20.0 °C 11:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 400 1+4 800 push 1 stop 20.0 °C 13:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Agent Shadow 1+4 400 20.0 °C 11:30 —
Verified Datasheet Report
Agent Shadow 1+4 800 push 1 stop 20.0 °C 13:00 —
Verified Datasheet Report
Agent Shadow 1+4 1600 push 2 stops 20.0 °C 17:00 —
Verified Datasheet Report
X FILM 320 Pro 1+4 320 20.0 °C 13:00 —
Verified Datasheet Report
X FILM 320 Pro 1+4 200 pull 0.75 stops 20.0 °C 8:00 —
Verified Datasheet Report
RPX 100 1+4 50 pull 1 stop 20.0 °C 8:00 —
Verified Datasheet Report
RPX 100 1+4 100 20.0 °C 9:00 —
Verified Datasheet Report
RPX 100 1+4 200 push 1 stop 20.0 °C 11:00 —
Verified Datasheet Report
RPX 400 1+4 400 20.0 °C 10:00 —
Verified Datasheet Report
RPX 400 1+4 800 push 1 stop 20.0 °C 12:00 —
Verified Datasheet Report
Retro 400S 1+4 400 20.0 °C 10:00 —
Verified Datasheet Report
Retro 400S 1+4 800 push 1 stop 20.0 °C 13:00 —
Verified Datasheet Report
SuperPan 200 1+4 200 20.0 °C 8:45 —
Verified Datasheet Report

Reuse

Checked 21 October 2026

Ilford says Ilford Ilfotec DD-X may be used for more than one film.

  • 1+4 may be reused

Longer time for reuse: +10 % development time for each successive film in a litre (N, N+10 %, N+20 % ...), up to N+90 % for film 10.

Capacity, as the maker states it: 1 litre of 1+4 working solution reused: up to 10 x 135/36 or 120 films. Per litre of concentrate: 16 films one-shot, up to 50 reused.

For the highest image quality ILFOTEC DD-X should be used as a one-shot developer, however for greater economy it can be reused to process either several films individually or multiple films in batches. ... 1 Litre of ILFOTEC DD-X 1+4 can process up to 10 x 135/36 or 120 roll films provided that the developer is reused. ... Used at 1+4 for one shot processing it will develop 16x135/36 films. If reuse techniques are used, it will develop up to 50x135/36 or 120 films. ... ILFOTEC DD-X working strength solutions should not be kept for more than 24 hours.

ILFORD ILFOTEC DD-X Technical Information (Harman/Ilford, Aug 2019, 8 pp.) ↗

Dilutions

  • 1+4 1 + 4 water
  • 1+9 1 + 9 water

Link to this page

Specification

Type
B&W developer
Form
Liquid concentrate
Capacity rolls per litre
10.0
Shelf life, unopened
—
Shelf life, opened
—

A dash means the figure has not been read off the maker’s sheet. A guess here would produce wrong answers silently.

Help keep it right

Suggest a time or report a mistake.

Know a time for Ilfotec DD-X that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.

0 reviews

Written by photographers, under their own profile — so you can see what they shoot before you weigh what they say.