B&W developer Liquid concentrate In production Reusable at some dilutions Replenishable

Development times

Showing 86 of 86 published times.

Film Dilution EI Temp Time Agitation Source
Pan F Plus 1+31 50 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan F Plus 1+11 25 pull 1 stop 24.0 °C 0:50 Machine — continuous
Verified Datasheet Report
Pan F Plus 1+11 50 24.0 °C 1:05 Machine — continuous
Verified Datasheet Report
FP4 Plus 1+15 125 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus 1+15 200 push 0.75 stops 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus 1+31 50 pull 1.25 stops 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus 1+31 125 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus 1+31 200 push 0.75 stops 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro 1+31 50 pull 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro 1+31 100 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro 1+31 200 push 1 stop 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+15 400 20.0 °C 3:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+15 800 push 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+15 1600 push 2 stops 20.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+15 3200 push 3 stops 20.0 °C 11:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+31 400 20.0 °C 6:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+31 800 push 1 stop 20.0 °C 9:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+31 1600 push 2 stops 20.0 °C 14:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 1+15 200 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 1+15 400 push 1 stop 20.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 1+15 800 push 2 stops 20.0 °C 10:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 1+31 200 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 1+31 400 push 1 stop 20.0 °C 13:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 1+31 800 push 2 stops 20.0 °C 19:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+15 320 pull 0.25 stops 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+15 800 push 1 stop 20.0 °C 5:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+15 1600 push 2 stops 20.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+15 3200 push 3 stops 20.0 °C 13:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+31 200 pull 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+31 400 20.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+31 800 push 1 stop 20.0 °C 10:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+31 1600 push 2 stops 20.0 °C 13:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+15 800 push 1 stop 24.0 °C 4:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+15 1600 push 2 stops 24.0 °C 5:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+15 3200 push 3 stops 24.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+31 200 pull 1 stop 24.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+31 400 24.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+31 800 push 1 stop 24.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+31 1600 push 2 stops 24.0 °C 10:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+15 1600 pull 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+15 3200 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+15 6400 push 1 stop 20.0 °C 13:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+31 400 pull 3 stops 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+31 800 pull 2 stops 20.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+31 1600 pull 1 stop 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+31 3200 20.0 °C 14:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+15 3200 24.0 °C 5:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+15 6400 push 1 stop 24.0 °C 8:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+31 400 pull 3 stops 24.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+31 800 pull 2 stops 24.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+31 1600 pull 1 stop 24.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 3200 Professional 1+31 3200 24.0 °C 10:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 100 1+31 100 20.0 °C 6:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 100 1+31 200 push 1 stop 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 200 1+15 200 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 200 1+15 400 push 1 stop 20.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 200 1+31 100 pull 1 stop 20.0 °C 4:45 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 200 1+31 200 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 200 1+31 400 push 1 stop 20.0 °C 10:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ortho Plus 1+15 80 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ortho Plus 1+31 80 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 100 1+15 100 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 1+15 200 push 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 1+31 50 pull 1 stop 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 1+31 100 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 1+31 200 push 1 stop 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 1+11 100 24.0 °C 1:10 Machine — continuous
Unverified Datasheet Report
Pan 400 1+15 400 20.0 °C 3:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+15 800 push 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+15 1600 push 2 stops 20.0 °C 7:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+15 3200 push 3 stops 20.0 °C 11:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+31 200 pull 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+31 400 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+31 800 push 1 stop 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+31 1600 push 2 stops 20.0 °C 14:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+11 200 pull 1 stop 24.0 °C 0:50 Machine — continuous
Unverified Datasheet Report
Pan 400 1+11 400 24.0 °C 0:55 Machine — continuous
Unverified Datasheet Report
Pan 400 1+11 800 push 1 stop 24.0 °C 1:10 Machine — continuous
Unverified Datasheet Report
Pan 400 1+11 1600 push 2 stops 24.0 °C 1:30 Machine — continuous
Unverified Datasheet Report
Pan 100 1+15 100 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 100 1+15 200 push 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 100 1+31 50 pull 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 400 1+15 400 20.0 °C 4:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 400 1+15 800 push 1 stop 20.0 °C 6:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 400 1+31 400 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Pan 400 1+31 800 push 1 stop 20.0 °C 12:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report

Reuse

Checked 21 October 2026

Ilford says whether Ilford Ilfotec HC may be reused depends on how it is used. It can also be replenished.

  • 1+11 use once
  • 1+15 may be reused
  • 1+31 may be reused

1+15: +10 % development time for each successive film in a litre (N, N+10 %, N+20 % ...), up to N+90 % for film 10.

1+31: +10 % development time for each successive film in a litre (N, N+10 %, N+20 % ...), up to N+40 % for film 5.

Capacity, as the maker states it: Reused working solution: 10 films per litre at 1+15, 5 films per litre at 1+31.

ILFOTEC HC 1+15 and 1+31 working strength developer in spiral tanks without replenishment to process either a number of films individually or multiple films in batches. ... The table below gives the number of 135/36 or 120 roll films a litre of working strength ILFOTEC HC can process provided that the developer is reused. ... ILFOTEC HC 1+15: 10 films/litre; ILFOTEC HC 1+31: 5 films/litre. ... We do not recommend reusing diluted developers, 1+47, always use fresh solutions on each occasion. ... Do not use ILFOTEC HC developer as replenisher.

ILFORD ILFOTEC HC Technical Information (Harman, June 2010, 13 pp.) ↗

Dilutions

  • 1+11 1 + 11 water
  • 1+15 1 + 15 water
  • 1+31 1 + 31 water

Link to this page

Specification

Type
B&W developer
Form
Liquid concentrate
Capacity rolls per litre
—
Shelf life, unopened
—
Shelf life, opened
—

A dash means the figure has not been read off the maker’s sheet. A guess here would produce wrong answers silently.

Help keep it right

Suggest a time or report a mistake.

Know a time for Ilfotec HC that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.

0 reviews

Written by photographers, under their own profile — so you can see what they shoot before you weigh what they say.