Development times
Showing 2 of 127 published times.
| Film | Dilution | EI | Temp | Time | Agitation | Source |
|---|---|---|---|---|---|---|
| Ilford Delta 100 Pro | 1+19 20.0 °C | 100 | 6:00 | Ilford — 4 inversions every 60 s | ||
| Ilford Delta 100 Pro | 1+29 20.0 °C | 100 | 7:30 | Ilford — 4 inversions every 60 s |
Reuse
Checked 21 October 2026
Ilford says whether Ilford Ilfotec LC29 may be reused depends on how it is used.
- 1+9 may be reused
- 1+19 may be reused
- 1+29 use once
1+9: +10 % development time for each successive film in a litre (N, N+10 %, N+20 % ...), up to N+90 % for film 10.
1+19: +10 % development time for each successive film in a litre (N, N+10 %, N+20 % ...), up to N+40 % for film 5.
Capacity, as the maker states it: Reused working solution: 10 films per litre at 1+9, 5 films per litre at 1+19; 1+29 is one-shot.
With ILFOTEC LC29 there is a choice of dilution - 1+29, 1+19 and 1+9 - and the option for either one-shot processing or for greater economy to reuse the diluted developer solution during one working session. ... Working strength solutions of ILFOSOL S 1+9 and 1+14 and ILFOTEC LC29 1+29 are described as a one-shot developers. They should be used only once and discarded, we do not recommend reusing them to process more than one film. ... For the highest image quality ILFOTEC DD-X 1+4 and ILFOTEC LC29 1+9 and 1+19 should also be used as one-shot developers. For greater economy they can be reused to process either a number of films individually or multiple films in batches.
ILFORD ILFOTEC DD-X, ILFOTEC LC29 AND ILFOSOL S FILM DEVELOPERS (Harman, June 2010, 10 pp.) ↗
Dilutions
- 1+9 1 + 9 water
- 1+19 1 + 19 water
- 1+29 1 + 29 water
Link to this page
Specification
- Type
- B&W developer
- Form
- Liquid concentrate
- Capacity rolls per litre
- —
- Shelf life, unopened
- —
- Shelf life, opened
- —
A dash means the figure has not been read off the maker’s sheet. A guess here would produce wrong answers silently.
Suggest a time or report a mistake
Know a time for Ilfotec LC29 that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.
- Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
- Nothing goes up by itself. Every report is read by a person before anything on the page changes.
- No account needed. Your name and email are optional, and only to reply to you.
0 reviews
Written by photographers, under their own profile — so you can see what they shoot before you weigh what they say.