Development times

Showing 287 of 287 published times.

Film Dilution EI Temp Time Agitation Source
T-Max 400 1+4 400 21.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 1+4 400 22.0 °C 6:00 —
Verified Datasheet Report
Pan F Plus 1+4 50 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus 1+4 125 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus 1+4 200 push 0.75 stops 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro 1+4 50 pull 1 stop 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro 1+4 100 20.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro 1+4 200 push 1 stop 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+4 400 20.0 °C 6:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+4 800 push 1 stop 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+4 1600 push 2 stops 20.0 °C 9:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ 1+4 3200 push 3 stops 20.0 °C 11:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 1+4 200 20.0 °C 8:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 1+4 400 push 1 stop 20.0 °C 10:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 1+4 800 push 2 stops 20.0 °C 12:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 200 pull 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 400 20.0 °C 6:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 500 push 0.25 stops 20.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 800 push 1 stop 20.0 °C 8:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 1600 push 2 stops 20.0 °C 10:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 3200 push 3 stops 20.0 °C 13:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 200 pull 1 stop 24.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 400 24.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 500 push 0.25 stops 24.0 °C 5:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 800 push 1 stop 24.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 1600 push 2 stops 24.0 °C 8:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional 1+4 3200 push 3 stops 24.0 °C 11:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 20.0 °C 12:15 —
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 21.0 °C 11:30 —
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 22.0 °C 10:45 —
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 24.0 °C 10:00 —
Verified Datasheet Report
T-Max 100 1+4 800 push 3 stops 24.0 °C 11:45 —
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 20.0 °C 12:15 —
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 21.0 °C 11:30 —
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 22.0 °C 10:45 —
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 24.0 °C 10:00 —
Verified Datasheet Report
T-Max 100 1+4 800 push 3 stops 24.0 °C 11:45 —
Verified Datasheet Report
Fomapan 100 Classic 1+4 100 20.0 °C 5:00 —
Verified Datasheet Report
Fomapan 200 Creative 1+4 200 20.0 °C 5:00 —
Verified Datasheet Report
Fomapan 400 Action 1+4 400 20.0 °C 7:00 —
Verified Datasheet Report
Pan 100 1+4 100 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 1+4 200 push 1 stop 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+4 200 pull 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+4 400 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+4 800 push 1 stop 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 1+4 1600 push 2 stops 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Mono 1+4 100 20.0 °C 5:00 —
Verified Datasheet Report
Agent Shadow 1+4 400 20.0 °C 5:30 —
Verified Datasheet Report
Agent Shadow 1+9 400 20.0 °C 10:00 —
Verified Datasheet Report
Agent Shadow 1+9 1600 push 2 stops 20.0 °C 18:00 —
Verified Datasheet Report
P30 1+6 80 24.0 °C 7:00 —
Verified Datasheet Report
X FILM 320 Pro 1+4 320 20.0 °C 9:30 —
Verified Datasheet Report
T-Max 400 1+4 400 22.0 °C 6:00 —
Verified Datasheet Report
T-Max 100 1+4 100 20.0 °C 8:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 1+4 100 21.0 °C 8:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 1+4 100 22.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 1+4 100 24.0 °C 7:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 1+4 100 20.0 °C 8:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 1+4 100 21.0 °C 8:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 1+4 100 22.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 1+4 100 24.0 °C 7:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 1+4 100 20.0 °C 7:45 —
Verified Datasheet Report
T-Max 100 1+4 100 21.0 °C 7:15 —
Verified Datasheet Report
T-Max 100 1+4 100 22.0 °C 6:45 —
Verified Datasheet Report
T-Max 100 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max 100 1+7 100 24.0 °C 9:30 —
Verified Datasheet Report
T-Max 100 1+9 100 24.0 °C 13:30 —
Verified Datasheet Report
T-Max 100 1+4 200 push 1 stop 20.0 °C 7:45 —
Verified Datasheet Report
T-Max 100 1+4 200 push 1 stop 24.0 °C 6:15 —
Verified Datasheet Report
T-Max 100 1+4 100 20.0 °C 7:45 —
Verified Datasheet Report
T-Max 100 1+4 100 21.0 °C 7:15 —
Verified Datasheet Report
T-Max 100 1+4 100 22.0 °C 6:45 —
Verified Datasheet Report
T-Max 100 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max 100 1+7 100 24.0 °C 9:30 —
Verified Datasheet Report
T-Max 100 1+9 100 24.0 °C 13:30 —
Verified Datasheet Report
T-Max 100 1+4 200 push 1 stop 20.0 °C 7:45 —
Verified Datasheet Report
T-Max 100 1+4 200 push 1 stop 24.0 °C 6:15 —
Verified Datasheet Report
T-Max 100 1+4 100 20.0 °C 7:30 —
Verified Datasheet Report
T-Max 100 1+4 100 21.0 °C 7:00 —
Verified Datasheet Report
T-Max 100 1+4 100 22.0 °C 6:30 —
Verified Datasheet Report
T-Max 100 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max 100 1+7 100 24.0 °C 9:30 —
Verified Datasheet Report
T-Max 100 1+9 100 24.0 °C 13:30 —
Verified Datasheet Report
T-Max 100 1+4 200 push 1 stop 20.0 °C 7:30 —
Verified Datasheet Report
T-Max 100 1+4 200 push 1 stop 24.0 °C 6:15 —
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 20.0 °C 12:15 —
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 24.0 °C 10:00 —
Verified Datasheet Report
T-Max 100 1+4 800 push 3 stops 24.0 °C 11:45 —
Verified Datasheet Report
T-Max 100 1+4 100 20.0 °C 7:30 —
Verified Datasheet Report
T-Max 100 1+4 100 21.0 °C 7:00 —
Verified Datasheet Report
T-Max 100 1+4 100 22.0 °C 6:30 —
Verified Datasheet Report
T-Max 100 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max 100 1+7 100 24.0 °C 9:30 —
Verified Datasheet Report
T-Max 100 1+9 100 24.0 °C 13:30 —
Verified Datasheet Report
T-Max 100 1+4 200 push 1 stop 20.0 °C 7:30 —
Verified Datasheet Report
T-Max 100 1+4 200 push 1 stop 24.0 °C 6:15 —
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 20.0 °C 12:15 —
Verified Datasheet Report
T-Max 100 1+4 400 push 2 stops 24.0 °C 10:00 —
Verified Datasheet Report
T-Max 100 1+4 800 push 3 stops 24.0 °C 11:45 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 21.0 °C 8:00 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 22.0 °C 7:30 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 20.0 °C 8:30 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 24.0 °C 6:30 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 27.0 °C 5:30 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 29.0 °C 4:30 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 20.0 °C 9:30 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 21.0 °C 9:00 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 22.0 °C 8:30 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 24.0 °C 7:30 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 27.0 °C 6:30 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 29.0 °C 5:30 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 20.0 °C 10:30 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 21.0 °C 10:00 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 22.0 °C 9:00 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 24.0 °C 8:00 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 27.0 °C 7:00 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 29.0 °C 6:00 —
Verified Datasheet Report
T-Max P3200 1+4 3200 20.0 °C 12:00 —
Verified Datasheet Report
T-Max P3200 1+4 3200 21.0 °C 11:30 —
Verified Datasheet Report
T-Max P3200 1+4 3200 22.0 °C 10:30 —
Verified Datasheet Report
T-Max P3200 1+4 3200 24.0 °C 9:30 —
Verified Datasheet Report
T-Max P3200 1+4 3200 27.0 °C 8:00 —
Verified Datasheet Report
T-Max P3200 1+4 3200 29.0 °C 6:30 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 20.0 °C 13:30 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 21.0 °C 13:00 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 22.0 °C 12:00 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 24.0 °C 11:00 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 27.0 °C 9:00 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 29.0 °C 7:30 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 20.0 °C 15:30 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 21.0 °C 14:30 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 22.0 °C 13:30 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 24.0 °C 12:00 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 27.0 °C 10:00 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 29.0 °C 8:30 —
Verified Datasheet Report
T-Max P3200 1+4 25000 push 3 stops 21.0 °C 16:00 —
Verified Datasheet Report
T-Max P3200 1+4 25000 push 3 stops 22.0 °C 15:00 —
Verified Datasheet Report
T-Max P3200 1+4 25000 push 3 stops 24.0 °C 13:30 —
Verified Datasheet Report
T-Max P3200 1+4 25000 push 3 stops 27.0 °C 11:30 —
Verified Datasheet Report
T-Max P3200 1+4 25000 push 3 stops 29.0 °C 9:30 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 20.0 °C 8:30 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 21.0 °C 8:00 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 22.0 °C 7:30 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 24.0 °C 6:30 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 27.0 °C 5:30 —
Verified Datasheet Report
T-Max P3200 1+4 400 pull 3 stops 29.0 °C 4:30 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 20.0 °C 9:30 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 21.0 °C 9:00 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 22.0 °C 8:30 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 24.0 °C 7:30 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 27.0 °C 6:30 —
Verified Datasheet Report
T-Max P3200 1+4 800 pull 2 stops 29.0 °C 5:30 —
Verified Datasheet Report
T-Max P3200 1+7 800 pull 2 stops 24.0 °C 13:00 —
Verified Datasheet Report
T-Max P3200 1+9 800 pull 2 stops 24.0 °C 19:30 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 20.0 °C 10:30 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 21.0 °C 10:00 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 22.0 °C 9:00 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 24.0 °C 8:00 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 27.0 °C 7:00 —
Verified Datasheet Report
T-Max P3200 1+4 1600 pull 1 stop 29.0 °C 6:00 —
Verified Datasheet Report
T-Max P3200 1+4 3200 20.0 °C 12:00 —
Verified Datasheet Report
T-Max P3200 1+4 3200 21.0 °C 11:30 —
Verified Datasheet Report
T-Max P3200 1+4 3200 22.0 °C 10:30 —
Verified Datasheet Report
T-Max P3200 1+4 3200 24.0 °C 9:30 —
Verified Datasheet Report
T-Max P3200 1+4 3200 27.0 °C 8:00 —
Verified Datasheet Report
T-Max P3200 1+4 3200 29.0 °C 6:30 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 20.0 °C 13:30 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 21.0 °C 13:00 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 22.0 °C 12:00 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 24.0 °C 11:00 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 27.0 °C 9:00 —
Verified Datasheet Report
T-Max P3200 1+4 6400 push 1 stop 29.0 °C 7:30 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 20.0 °C 15:30 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 21.0 °C 14:30 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 22.0 °C 13:30 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 24.0 °C 12:00 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 27.0 °C 10:00 —
Verified Datasheet Report
T-Max P3200 1+4 12500 push 2 stops 29.0 °C 8:30 —
Verified Datasheet Report
T-Max P3200 1+4 25000 push 3 stops 21.0 °C 16:00 —
Verified Datasheet Report
T-Max P3200 1+4 25000 push 3 stops 22.0 °C 15:00 —
Verified Datasheet Report
T-Max P3200 1+4 25000 push 3 stops 24.0 °C 13:30 —
Verified Datasheet Report
T-Max P3200 1+4 25000 push 3 stops 27.0 °C 11:30 —
Verified Datasheet Report
T-Max P3200 1+4 25000 push 3 stops 29.0 °C 9:30 —
Verified Datasheet Report
T-Max 400 1+4 400 24.0 °C 5:30 —
Verified Datasheet Report
Tri-X 1+4 320 18.0 °C 8:15 —
Verified Datasheet Report
Tri-X 1+4 320 20.0 °C 7:15 —
Verified Datasheet Report
Tri-X 1+4 320 21.0 °C 6:45 —
Verified Datasheet Report
Tri-X 1+4 320 22.0 °C 6:15 —
Verified Datasheet Report
Tri-X 1+4 320 24.0 °C 5:15 —
Verified Datasheet Report
Tri-X 1+4 320 18.0 °C 8:15 —
Verified Datasheet Report
Tri-X 1+4 320 20.0 °C 7:15 —
Verified Datasheet Report
Tri-X 1+4 320 21.0 °C 6:45 —
Verified Datasheet Report
Tri-X 1+4 320 22.0 °C 6:15 —
Verified Datasheet Report
Tri-X 1+4 320 24.0 °C 5:15 —
Verified Datasheet Report
Plus-X Pan 1+4 125 18.0 °C 6:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 20.0 °C 5:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 21.0 °C 5:15 —
Verified Datasheet Report
Plus-X Pan 1+4 125 22.0 °C 4:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 24.0 °C 4:15 —
Verified Datasheet Report
Plus-X Pan 1+4 500 push 2 stops 20.0 °C 8:45 —
Verified Datasheet Report
Plus-X Pan 1+4 500 push 2 stops 21.0 °C 8:00 —
Verified Datasheet Report
Plus-X Pan 1+4 500 push 2 stops 22.0 °C 7:15 —
Verified Datasheet Report
Plus-X Pan 1+4 500 push 2 stops 24.0 °C 6:15 —
Verified Datasheet Report
Plus-X Pan 1+4 125 18.0 °C 6:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 20.0 °C 5:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 21.0 °C 5:15 —
Verified Datasheet Report
Plus-X Pan 1+4 125 22.0 °C 4:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 24.0 °C 4:15 —
Verified Datasheet Report
Plus-X Pan 1+4 500 push 2 stops 20.0 °C 8:45 —
Verified Datasheet Report
Plus-X Pan 1+4 500 push 2 stops 21.0 °C 8:00 —
Verified Datasheet Report
Plus-X Pan 1+4 500 push 2 stops 22.0 °C 7:15 —
Verified Datasheet Report
Plus-X Pan 1+4 500 push 2 stops 24.0 °C 6:15 —
Verified Datasheet Report
Plus-X Pan 1+4 125 18.0 °C 6:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 20.0 °C 5:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 21.0 °C 5:15 —
Verified Datasheet Report
Plus-X Pan 1+4 125 22.0 °C 4:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 24.0 °C 4:15 —
Verified Datasheet Report
Plus-X Pan 1+4 500 push 2 stops 24.0 °C 6:15 —
Verified Datasheet Report
Plus-X Pan 1+4 125 18.0 °C 6:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 20.0 °C 5:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 21.0 °C 5:15 —
Verified Datasheet Report
Plus-X Pan 1+4 125 22.0 °C 4:45 —
Verified Datasheet Report
Plus-X Pan 1+4 125 24.0 °C 4:15 —
Verified Datasheet Report
Plus-X Pan 1+4 500 push 2 stops 24.0 °C 6:15 —
Verified Datasheet Report
Verichrome Pan 1+4 125 push 0.75 stops 20.0 °C 6:00 —
Verified Datasheet Report
Verichrome Pan 1+4 125 push 0.75 stops 21.0 °C 5:30 —
Verified Datasheet Report
Verichrome Pan 1+4 125 push 0.75 stops 22.0 °C 5:00 —
Verified Datasheet Report
Verichrome Pan 1+4 125 push 0.75 stops 24.0 °C 4:00 —
Verified Datasheet Report
RPX 100 1+4 100 20.0 °C 7:00 —
Verified Datasheet Report
RPX 100 1+4 200 push 1 stop 20.0 °C 10:00 —
Verified Datasheet Report
RPX 400 1+4 400 20.0 °C 7:00 —
Verified Datasheet Report
RPX 400 1+9 400 20.0 °C 10:00 —
Verified Datasheet Report
RPX 400 1+9 1600 push 2 stops 20.0 °C 18:00 —
Verified Datasheet Report
Retro 80S 1+4 80 20.0 °C 9:00 —
Verified Datasheet Report
Retro 400S 1+4 400 20.0 °C 7:00 —
Verified Datasheet Report
Retro 400S 1+9 400 20.0 °C 10:00 —
Verified Datasheet Report
Retro 400S 1+9 1600 push 2 stops 20.0 °C 18:00 —
Verified Datasheet Report
SuperPan 200 1+4 200 20.0 °C 8:00 —
Verified Datasheet Report
Ortho 25 Plus 1+4 25 20.0 °C 7:00 —
Verified Datasheet Report
T-Max 400 1+4 400 20.0 °C 7:30 —
Verified Datasheet Report
T-Max 400 1+4 400 21.0 °C 7:15 —
Verified Datasheet Report
T-Max 400 1+4 400 22.0 °C 6:45 —
Verified Datasheet Report
T-Max 400 1+4 400 24.0 °C 6:00 —
Verified Datasheet Report
T-Max 400 1+4 400 20.0 °C 7:30 —
Verified Datasheet Report
T-Max 400 1+4 400 21.0 °C 7:15 —
Verified Datasheet Report
T-Max 400 1+4 400 22.0 °C 6:45 —
Verified Datasheet Report
T-Max 400 1+4 400 24.0 °C 6:00 —
Verified Datasheet Report
T-Max 400 1+4 400 20.0 °C 6:45 —
Verified Datasheet Report
T-Max 400 1+4 400 21.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 1+7 400 24.0 °C 8:15 —
Verified Datasheet Report
T-Max 400 1+9 400 24.0 °C 13:45 —
Verified Datasheet Report
T-Max 400 1+4 400 20.0 °C 6:45 —
Verified Datasheet Report
T-Max 400 1+4 400 21.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 1+4 400 22.0 °C 6:00 —
Verified Datasheet Report
T-Max 400 1+4 400 24.0 °C 5:30 —
Verified Datasheet Report
T-Max 400 1+7 400 24.0 °C 8:15 —
Verified Datasheet Report
T-Max 400 1+9 400 24.0 °C 13:45 —
Verified Datasheet Report
T-Max 400 1+4 400 20.0 °C 6:45 —
Verified Datasheet Report
T-Max 400 1+4 400 24.0 °C 5:30 —
Verified Datasheet Report
T-Max 400 1+7 400 24.0 °C 8:15 —
Verified Datasheet Report
T-Max 400 1+9 400 24.0 °C 13:45 —
Verified Datasheet Report
T-Max 400 1+4 400 20.0 °C 6:45 —
Verified Datasheet Report
T-Max 400 1+4 400 21.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 1+4 400 22.0 °C 6:00 —
Verified Datasheet Report
T-Max 400 1+4 400 24.0 °C 5:30 —
Verified Datasheet Report
T-Max 400 1+7 400 24.0 °C 8:15 —
Verified Datasheet Report
T-Max 400 1+9 400 24.0 °C 13:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 18.0 °C 6:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 20.0 °C 6:00 —
Verified Datasheet Report
Tri-X 400 1+4 400 21.0 °C 5:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 22.0 °C 5:30 —
Verified Datasheet Report
Tri-X 400 1+4 400 24.0 °C 4:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 18.0 °C 6:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 20.0 °C 6:00 —
Verified Datasheet Report
Tri-X 400 1+4 400 21.0 °C 5:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 22.0 °C 5:30 —
Verified Datasheet Report
Tri-X 400 1+4 400 24.0 °C 4:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 18.0 °C 6:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 20.0 °C 6:00 —
Verified Datasheet Report
Tri-X 400 1+4 400 21.0 °C 5:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 22.0 °C 5:30 —
Verified Datasheet Report
Tri-X 400 1+4 400 24.0 °C 4:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 18.0 °C 6:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 20.0 °C 6:00 —
Verified Datasheet Report
Tri-X 400 1+4 400 21.0 °C 5:45 —
Verified Datasheet Report
Tri-X 400 1+4 400 22.0 °C 5:30 —
Verified Datasheet Report
Tri-X 400 1+4 400 24.0 °C 4:45 —
Verified Datasheet Report

Reuse

Checked 21 October 2026

Kodak says Kodak T-Max Developer may be used for more than one film.

The maker doesn’t publish a rule for lengthening the time, so the calculator makes no correction.

The capacity of this developer with normal processing is approximately 48 rolls of 135-36 or 120 film per gallon (or equivalent), with time compensation. ... Discard the developer after you process 48 rolls of film. ... Note: Do not use T-MAX RS Developer and Replenisher to replenish T-MAX Developer. ... T-MAX Developer is intended for use in unreplenished systems.

KODAK PROFESSIONAL T-MAX Developers (KODAK Publication J-86, October 2002, p.9; and Dec 2017 edition) ↗

Dilutions

  • 1+4 1 + 4 water
  • 1+7 1 + 7 water
  • 1+9 1 + 9 water
  • 1+6 1 + 6 water

Link to this page

Specification

Type
B&W developer
Form
Liquid concentrate
Capacity rolls per litre
—
Shelf life, unopened
—
Shelf life, opened
—

A dash means the figure has not been read off the maker’s sheet. A guess here would produce wrong answers silently.

Help keep it right

Suggest a time or report a mistake.

Know a time for T-Max Developer that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.

0 reviews

Written by photographers, under their own profile — so you can see what they shoot before you weigh what they say.