Skip to content

Development times

Agfa-Gevaert Agfapan APX 25 in ADOX Rodinal

16 published times at 1+25, 1+50, rated at EI 20–25, 18.0–24.0 °C. Each one is linked to the datasheet or chart it was read from.

Open in the calculator

At box speed

11:00

Open in the calculator ›

Speed

EI 25

Dilution

1+50

Temperature

18.0 °C

Embed Show this time on your own site

The card shows the time, its source and a link back here. It sets no cookies and loads nothing from other sites. More options are in the API documentation.

Preview

Every published time

Showing 16 of 16 published times.

Developer Dilution EI Temp Time Agitation Source
Rodinal 1+25 20 pull 0.25 stops 18.0 °C 5:00 Rotary — continuous rotation
Verified Datasheet Report
Rodinal 1+25 20 pull 0.25 stops 18.0 °C 7:00 —
Verified Datasheet Report
Rodinal 1+25 20 pull 0.25 stops 20.0 °C 4:00 Rotary — continuous rotation
Verified Datasheet Report
Rodinal 1+25 20 pull 0.25 stops 20.0 °C 6:00 —
Verified Datasheet Report
Rodinal 1+25 20 pull 0.25 stops 22.0 °C 3:30 Rotary — continuous rotation
Verified Datasheet Report
Rodinal 1+25 20 pull 0.25 stops 22.0 °C 5:00 —
Verified Datasheet Report
Rodinal 1+25 20 pull 0.25 stops 24.0 °C 3:00 Rotary — continuous rotation
Verified Datasheet Report
Rodinal 1+25 20 pull 0.25 stops 24.0 °C 4:00 —
Verified Datasheet Report
Rodinal 1+50 25 18.0 °C 11:00 Rotary — continuous rotation
Verified Datasheet Report
Rodinal 1+50 25 18.0 °C 12:00 —
Verified Datasheet Report
Rodinal 1+50 25 20.0 °C 9:00 Rotary — continuous rotation
Verified Datasheet Report
Rodinal 1+50 25 20.0 °C 10:00 —
Verified Datasheet Report
Rodinal 1+50 25 22.0 °C 8:00 Rotary — continuous rotation
Verified Datasheet Report
Rodinal 1+50 25 22.0 °C 9:00 —
Verified Datasheet Report
Rodinal 1+50 25 24.0 °C 7:00 Rotary — continuous rotation
Verified Datasheet Report
Rodinal 1+50 25 24.0 °C 8:00 —
Verified Datasheet Report

Help keep it right

Suggest a time or report a mistake.

Know a time for Agfapan APX 25 in Rodinal that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.