15 published times at 1+31, 1+15, rated at EI 200–3200, 20.0–24.0 °C. Each one is linked to the datasheet or chart it was read from.

Open in the calculator

At box speed

7:30

Open in the calculator ›

Speed

EI 400

Dilution

1+31

Temperature

20.0 °C

Every published time

Showing 15 of 15 published times.

Developer Dilution EI Temp Time Agitation Source
Ilfotec HC 1+31 200 pull 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+31 200 pull 1 stop 24.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+15 320 pull 0.25 stops 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+31 400 20.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+31 400 24.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+15 800 push 1 stop 20.0 °C 5:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+31 800 push 1 stop 20.0 °C 10:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+15 800 push 1 stop 24.0 °C 4:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+31 800 push 1 stop 24.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+15 1600 push 2 stops 20.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+31 1600 push 2 stops 20.0 °C 13:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+15 1600 push 2 stops 24.0 °C 5:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+31 1600 push 2 stops 24.0 °C 10:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+15 3200 push 3 stops 20.0 °C 13:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilfotec HC 1+15 3200 push 3 stops 24.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report

Help keep it right

Suggest a time or report a mistake.

Know a time for Delta 400 Professional in Ilfotec HC that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.