Skip to content

Development times

Kentmere Pan 200 in Kodak D-76

5 published times at stock, 1+1, 1+3, rated at EI 100–200, 20.0 °C. Each one is linked to the datasheet or chart it was read from.

Open in the calculator

At box speed

7:30

Open in the calculator ›

Speed

EI 200

Dilution

stock

Temperature

20.0 °C

Embed Show this time on your own site

The card shows the time, its source and a link back here. It sets no cookies and loads nothing from other sites. More options are in the API documentation.

Preview

Every published time

Showing 5 of 5 published times.

Developer Dilution EI Temp Time Agitation Source
D-76 stock 100 pull 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
D-76 1+1 100 pull 1 stop 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
D-76 1+3 100 pull 1 stop 20.0 °C 12:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
D-76 stock 200 20.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
D-76 1+1 200 20.0 °C 8:45 Ilford — 4 inversions every 60 s
Verified Datasheet Report

Help keep it right

Suggest a time or report a mistake.

Know a time for Pan 200 in D-76 that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.