Skip to content

Development times

Kodak Tri-X in Kodak XTOL

98 published times at stock, 1+1, rated at EI 320–1250, 18.0–24.0 °C. Each one is linked to the datasheet or chart it was read from.

Open in the calculator

At box speed

6:00

Open in the calculator ›

Speed

EI 320

Dilution

stock

Temperature

18.0 °C

Embed Show this time on your own site

The card shows the time, its source and a link back here. It sets no cookies and loads nothing from other sites. More options are in the API documentation.

Preview

Every published time

Showing 98 of 98 published times.

Developer Dilution EI Temp Time Agitation Source
XTOL stock 320 18.0 °C 6:00 —
Verified Datasheet Report
XTOL stock 320 18.0 °C 6:45 —
Verified Datasheet Report
XTOL 1+1 320 18.0 °C 8:15 —
Verified Datasheet Report
XTOL stock 320 18.0 °C 8:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 320 18.0 °C 8:45 —
Verified Datasheet Report
XTOL stock 320 18.0 °C 8:45 —
Verified Datasheet Report
XTOL 1+1 320 18.0 °C 9:30 —
Verified Datasheet Report
XTOL stock 320 18.0 °C 10:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 18.0 °C 12:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 18.0 °C 12:30 —
Verified Datasheet Report
XTOL 1+1 320 18.0 °C 12:30 —
Verified Datasheet Report
XTOL stock 320 20.0 °C 5:15 —
Verified Datasheet Report
XTOL stock 320 20.0 °C 6:00 —
Verified Datasheet Report
XTOL 1+1 320 20.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 320 20.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 320 20.0 °C 7:45 —
Verified Datasheet Report
XTOL stock 320 20.0 °C 7:45 —
Verified Datasheet Report
XTOL 1+1 320 20.0 °C 8:30 —
Verified Datasheet Report
XTOL stock 320 20.0 °C 9:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 20.0 °C 10:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 20.0 °C 11:15 —
Verified Datasheet Report
XTOL 1+1 320 20.0 °C 11:15 —
Verified Datasheet Report
XTOL stock 320 21.0 °C 4:45 —
Verified Datasheet Report
XTOL stock 320 21.0 °C 5:30 —
Verified Datasheet Report
XTOL 1+1 320 21.0 °C 6:45 —
Verified Datasheet Report
XTOL stock 320 21.0 °C 7:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 320 21.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 320 21.0 °C 7:15 —
Verified Datasheet Report
XTOL 1+1 320 21.0 °C 7:45 —
Verified Datasheet Report
XTOL stock 320 21.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 21.0 °C 9:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 21.0 °C 10:15 —
Verified Datasheet Report
XTOL 1+1 320 21.0 °C 10:15 —
Verified Datasheet Report
XTOL stock 320 22.0 °C 4:30 —
Verified Datasheet Report
XTOL stock 320 22.0 °C 5:00 —
Verified Datasheet Report
XTOL stock 320 22.0 °C 6:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 22.0 °C 6:15 —
Verified Datasheet Report
XTOL stock 320 22.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 320 22.0 °C 6:30 —
Verified Datasheet Report
XTOL 1+1 320 22.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 320 22.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 22.0 °C 9:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 22.0 °C 9:30 —
Verified Datasheet Report
XTOL 1+1 320 22.0 °C 9:30 —
Verified Datasheet Report
XTOL stock 320 24.0 °C 4:00 —
Verified Datasheet Report
XTOL stock 320 24.0 °C 4:30 —
Verified Datasheet Report
XTOL stock 320 24.0 °C 5:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 24.0 °C 5:30 —
Verified Datasheet Report
XTOL stock 320 24.0 °C 5:45 —
Verified Datasheet Report
XTOL stock 320 24.0 °C 5:45 —
Verified Datasheet Report
XTOL 1+1 320 24.0 °C 6:15 —
Verified Datasheet Report
XTOL stock 320 24.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 24.0 °C 7:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 320 24.0 °C 8:00 —
Verified Datasheet Report
XTOL 1+1 320 24.0 °C 8:00 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 18.0 °C 8:30 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 18.0 °C 9:45 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 18.0 °C 11:45 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 18.0 °C 12:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 1250 push 2 stops 18.0 °C 13:30 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 18.0 °C 13:30 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 18.0 °C 13:30 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 18.0 °C 15:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 1250 push 2 stops 20.0 °C 7:30 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 20.0 °C 8:45 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 20.0 °C 10:30 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 20.0 °C 10:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 1250 push 2 stops 20.0 °C 12:00 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 20.0 °C 12:00 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 20.0 °C 12:00 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 20.0 °C 13:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 20.0 °C 15:45 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 20.0 °C 15:45 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 21.0 °C 7:00 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 21.0 °C 8:00 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 21.0 °C 9:30 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 21.0 °C 10:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 1250 push 2 stops 21.0 °C 11:00 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 21.0 °C 11:00 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 21.0 °C 11:00 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 21.0 °C 12:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 21.0 °C 14:30 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 21.0 °C 14:30 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 22.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 22.0 °C 7:30 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 22.0 °C 8:45 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 22.0 °C 9:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 22.0 °C 10:15 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 24.0 °C 5:45 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 24.0 °C 6:30 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 24.0 °C 7:45 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 24.0 °C 8:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 1250 push 2 stops 24.0 °C 8:45 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 24.0 °C 8:45 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 24.0 °C 8:45 —
Verified Datasheet Report
XTOL stock 1250 push 2 stops 24.0 °C 10:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 24.0 °C 11:30 —
Verified Datasheet Report
XTOL 1+1 1250 push 2 stops 24.0 °C 11:30 —
Verified Datasheet Report

Help keep it right

Suggest a time or report a mistake.

Know a time for Tri-X in XTOL that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.