Skip to content

Eastman Kodak Company

HC-110

B&W developer Liquid concentrate In production Reusable Replenishable

Development times

Showing 438 of 438 published times.

Film Dilution EI Temp Time Agitation Source
T-Max 400 Dilution B (1+31) 400 18.0 °C 5:45 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 20.0 °C 5:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 21.0 °C 4:45 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 22.0 °C 4:30 —
Verified Datasheet Report
Pan F Plus Dilution B (1+31) 50 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus Dilution A (1+15) 125 20.0 °C 4:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus Dilution A (1+15) 200 push 0.75 stops 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus Dilution B (1+31) 50 pull 1.25 stops 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus Dilution B (1+31) 125 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
FP4 Plus Dilution B (1+31) 200 push 0.75 stops 20.0 °C 12:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro Dilution B (1+31) 50 pull 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro Dilution B (1+31) 100 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford Delta 100 Pro Dilution B (1+31) 200 push 1 stop 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ Dilution A (1+15) 400 20.0 °C 2:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ Dilution A (1+15) 800 push 1 stop 20.0 °C 3:45 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ Dilution A (1+15) 1600 push 2 stops 20.0 °C 5:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ Dilution A (1+15) 3200 push 3 stops 20.0 °C 9:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ Dilution B (1+31) 400 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ Dilution B (1+31) 800 push 1 stop 20.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Ilford HP5+ Dilution B (1+31) 1600 push 2 stops 20.0 °C 11:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 Dilution A (1+15) 200 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 Dilution A (1+15) 400 push 1 stop 20.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 Dilution A (1+15) 800 push 2 stops 20.0 °C 10:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 Dilution B (1+31) 200 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 Dilution B (1+31) 400 push 1 stop 20.0 °C 13:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
SFX 200 Dilution B (1+31) 800 push 2 stops 20.0 °C 19:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution A (1+15) 320 pull 0.25 stops 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution A (1+15) 800 push 1 stop 20.0 °C 5:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution A (1+15) 1600 push 2 stops 20.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution A (1+15) 3200 push 3 stops 20.0 °C 13:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution B (1+31) 200 pull 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution B (1+31) 400 20.0 °C 7:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution B (1+31) 800 push 1 stop 20.0 °C 10:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution B (1+31) 1600 push 2 stops 20.0 °C 13:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution A (1+15) 800 push 1 stop 24.0 °C 4:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution A (1+15) 1600 push 2 stops 24.0 °C 5:30 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution A (1+15) 3200 push 3 stops 24.0 °C 8:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution B (1+31) 200 pull 1 stop 24.0 °C 4:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution B (1+31) 400 24.0 °C 5:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution B (1+31) 800 push 1 stop 24.0 °C 7:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
Delta 400 Professional Dilution B (1+31) 1600 push 2 stops 24.0 °C 10:00 Ilford — 4 inversions every 60 s
Verified Datasheet Report
CHS 100 II Dilution B (1+31) 100 20.0 °C 5:30 Kodak — 30 s initial, then 5 s every 30 s
Verified Datasheet Report
CHS 100 II Dilution D (1+39) 100 20.0 °C 7:00 Kodak — 30 s initial, then 5 s every 30 s
Verified Datasheet Report
CHS 100 II Dilution E (1+47) 100 20.0 °C 9:00 Kodak — 30 s initial, then 5 s every 30 s
Verified Datasheet Report
CHS 100 II Dilution B (1+31) 100 20.0 °C 5:30 Kodak — 30 s initial, then 5 s every 30 s
Verified Datasheet Report
CHS 100 II Dilution D (1+39) 100 20.0 °C 7:00 Kodak — 30 s initial, then 5 s every 30 s
Verified Datasheet Report
CHS 100 II Dilution E (1+47) 100 20.0 °C 9:00 Kodak — 30 s initial, then 5 s every 30 s
Verified Datasheet Report
Pancro 400 Dilution B (1+31) 400 20.0 °C 9:00 —
Verified Datasheet Report
Pancro 400 Dilution B (1+31) 400 21.0 °C 8:20 —
Verified Datasheet Report
Pancro 400 Dilution B (1+31) 400 22.0 °C 7:40 —
Verified Datasheet Report
Pancro 400 Dilution B (1+31) 400 24.0 °C 6:30 —
Verified Datasheet Report
'P' Dilution A (1+15) 100 20.0 °C 4:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 20.0 °C 11:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 21.0 °C 10:15 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 22.0 °C 9:15 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 24.0 °C 7:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 21.0 °C 10:15 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 22.0 °C 9:15 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 24.0 °C 7:45 —
Verified Datasheet Report
Fomapan 400 Action Dilution B (1+31) 400 20.0 °C 6:30 —
Verified Datasheet Report
Retropan 320 Soft Dilution B (1+31) 320 20.0 °C 7:00 —
Verified Datasheet Report
Retropan 320 Soft Dilution B (1+31) 640 push 1 stop 20.0 °C 11:00 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 400 18.0 °C 6:00 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 400 20.0 °C 5:00 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 400 22.0 °C 4:15 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 400 24.0 °C 3:30 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 400 26.0 °C 3:00 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 800 push 1 stop 18.0 °C 8:30 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 800 push 1 stop 20.0 °C 7:15 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 800 push 1 stop 22.0 °C 6:00 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 800 push 1 stop 24.0 °C 5:00 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 800 push 1 stop 26.0 °C 4:15 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 1600 push 2 stops 18.0 °C 14:30 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 1600 push 2 stops 20.0 °C 12:00 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 1600 push 2 stops 22.0 °C 10:00 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 1600 push 2 stops 24.0 °C 8:15 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 1600 push 2 stops 26.0 °C 7:00 —
Verified Datasheet Report
'Y' Dilution A (1+15) 100 20.0 °C 4:30 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 400 18.0 °C 6:15 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 400 20.0 °C 5:15 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 400 22.0 °C 4:30 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 400 24.0 °C 3:45 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 400 26.0 °C 3:15 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 800 push 1 stop 18.0 °C 9:00 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 800 push 1 stop 20.0 °C 7:30 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 800 push 1 stop 22.0 °C 6:15 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 800 push 1 stop 24.0 °C 5:15 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 800 push 1 stop 26.0 °C 4:30 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 1600 push 2 stops 18.0 °C 14:30 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 1600 push 2 stops 20.0 °C 12:00 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 1600 push 2 stops 22.0 °C 10:00 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 1600 push 2 stops 24.0 °C 8:30 —
Verified Datasheet Report
Neopan 400 Professional Dilution B (1+31) 1600 push 2 stops 26.0 °C 7:15 —
Verified Datasheet Report
'V' Dilution A (1+15) 100 20.0 °C 4:30 —
Verified Datasheet Report
Neopan 1600 Professional Dilution B (1+31) 800 pull 1 stop 18.0 °C 5:30 —
Verified Datasheet Report
Neopan 1600 Professional Dilution B (1+31) 800 pull 1 stop 20.0 °C 4:45 —
Verified Datasheet Report
Neopan 1600 Professional Dilution B (1+31) 800 pull 1 stop 22.0 °C 4:00 —
Verified Datasheet Report
Neopan 1600 Professional Dilution B (1+31) 800 pull 1 stop 24.0 °C 3:30 —
Verified Datasheet Report
Neopan 1600 Professional Dilution B (1+31) 1600 18.0 °C 8:15 —
Verified Datasheet Report
Neopan 1600 Professional Dilution B (1+31) 1600 20.0 °C 7:00 —
Verified Datasheet Report
Neopan 1600 Professional Dilution B (1+31) 1600 22.0 °C 5:45 —
Verified Datasheet Report
Neopan 1600 Professional Dilution B (1+31) 1600 24.0 °C 5:00 —
Verified Datasheet Report
Neopan 1600 Professional Dilution B (1+31) 1600 26.0 °C 4:15 —
Verified Datasheet Report
Pan 100 Dilution A (1+15) 100 20.0 °C 4:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 Dilution A (1+15) 200 push 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 Dilution B (1+31) 50 pull 1 stop 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 Dilution B (1+31) 100 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 100 Dilution B (1+31) 200 push 1 stop 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 Dilution A (1+15) 400 20.0 °C 3:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 Dilution A (1+15) 800 push 1 stop 20.0 °C 5:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 Dilution A (1+15) 1600 push 2 stops 20.0 °C 7:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 Dilution B (1+31) 400 20.0 °C 6:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 Dilution B (1+31) 800 push 1 stop 20.0 °C 9:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Pan 400 Dilution B (1+31) 1600 push 2 stops 20.0 °C 14:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Lady Grey 400 Dilution B (1+31) 400 20.0 °C 5:30 —
Verified Datasheet Report
Earl Grey Dilution B (1+31) 100 20.0 °C 6:30 —
Verified Datasheet Report
Berlin 400 Dilution B (1+31) 400 20.0 °C 8:07 —
Verified Datasheet Report
Fantome Kino Dilution B (1+31) 8 20.0 °C 7:00 —
Verified Datasheet Report
Babylon Kino Dilution B (1+31) 13 20.0 °C 8:30 —
Verified Datasheet Report
Orca Dilution B (1+31) 100 20.0 °C 8:07 —
Verified Datasheet Report
Agent Shadow Dilution B (1+31) 400 20.0 °C 5:00 —
Verified Datasheet Report
Agent Shadow Dilution E (1+47) 400 20.0 °C 8:00 —
Verified Datasheet Report
Agent Shadow Dilution E (1+47) 800 push 1 stop 20.0 °C 13:00 —
Verified Datasheet Report
P30 Dilution H (1+63) 80 20.0 °C 12:00 —
Verified Datasheet Report
P30 Dilution B (1+31) 80 20.0 °C 5:00 —
Verified Datasheet Report
'F' Dilution A (1+15) 100 20.0 °C 4:30 —
Verified Datasheet Report
'K' Dilution B (1+31) 100 24.0 °C 5:00 —
Verified Datasheet Report
WolfMan Dilution H (1+63) 100 20.0 °C 12:00 —
Verified Datasheet Report
S25 Dilution F (1+79) 25 20.0 °C 10:00 —
Verified Datasheet Report
U200 Dilution B (1+31) 200 20.0 °C 4:30 —
Verified Datasheet Report
U400 Dilution B (1+31) 400 20.0 °C 5:00 —
Verified Datasheet Report
WolfMan Dilution B (1+31) 100 20.0 °C 6:00 —
Verified Datasheet Report
WolfMan Dilution H (1+63) 100 20.0 °C 12:00 —
Verified Datasheet Report
WolfMan Dilution B (1+31) 100 20.0 °C 6:00 —
Verified Datasheet Report
Frankenstein Dilution B (1+31) 200 20.0 °C 4:00 —
Verified Datasheet Report
Frankenstein Dilution H (1+63) 200 20.0 °C 9:00 —
Verified Datasheet Report
Frankenstein Dilution B (1+31) 200 20.0 °C 4:00 —
Verified Datasheet Report
Frankenstein Dilution H (1+63) 200 20.0 °C 9:00 —
Verified Datasheet Report
Frankenstein Dilution B (1+31) 200 20.0 °C 4:00 —
Verified Datasheet Report
Frankenstein Dilution H (1+63) 200 20.0 °C 9:00 —
Verified Datasheet Report
Eastman Kodak Hi-Fi 2374 Dilution H (1+63) 50 20.0 °C 7:30 —
Verified Datasheet Report
Eastman Kodak Hi-Fi 2374 Dilution H (1+63) 100 push 1 stop 20.0 °C 8:30 —
Verified Datasheet Report
BW IR Dilution B (1+31) 200 20.0 °C 7:00 —
Verified Datasheet Report
Sonic 25 BW Film Dilution H (1+63) 25 20.0 °C 11:00 —
Verified Datasheet Report
Xtreme 100 Dilution B (1+31) 100 20.0 °C 8:30 —
Verified Datasheet Report
Xtreme 400 Dilution B (1+31) 400 20.0 °C 5:00 —
Verified Datasheet Report
X FILM 320 Pro 1+49 200 pull 0.75 stops 20.0 °C 10:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 18.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 20.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 21.0 °C 6:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 22.0 °C 5:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 24.0 °C 4:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 18.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 20.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 21.0 °C 6:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 22.0 °C 5:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 24.0 °C 4:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 18.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 20.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 21.0 °C 6:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 22.0 °C 5:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 24.0 °C 4:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 18.0 °C 7:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 20.0 °C 5:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 21.0 °C 5:15 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 22.0 °C 4:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 24.0 °C 4:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 200 push 1 stop 20.0 °C 5:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 200 push 1 stop 24.0 °C 4:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 18.0 °C 7:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 20.0 °C 5:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 21.0 °C 5:15 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 22.0 °C 4:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 24.0 °C 4:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 200 push 1 stop 20.0 °C 5:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 200 push 1 stop 24.0 °C 4:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 20.0 °C 11:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 18.0 °C 7:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 20.0 °C 5:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 21.0 °C 5:15 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 22.0 °C 4:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 24.0 °C 4:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 200 push 1 stop 20.0 °C 5:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 200 push 1 stop 24.0 °C 4:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 20.0 °C 11:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 21.0 °C 10:15 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 22.0 °C 9:15 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 24.0 °C 7:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 18.0 °C 6:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 20.0 °C 6:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 21.0 °C 5:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 22.0 °C 5:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 24.0 °C 4:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 200 push 1 stop 20.0 °C 6:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 200 push 1 stop 24.0 °C 4:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 20.0 °C 11:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 24.0 °C 7:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 18.0 °C 6:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 20.0 °C 6:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 21.0 °C 5:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 22.0 °C 5:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 24.0 °C 4:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 200 push 1 stop 20.0 °C 6:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 200 push 1 stop 24.0 °C 4:00 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 20.0 °C 11:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 400 push 2 stops 24.0 °C 7:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 18.0 °C 6:15 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 20.0 °C 5:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 21.0 °C 4:45 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 22.0 °C 4:30 —
Verified Datasheet Report
T-Max 100 Dilution B (1+31) 100 24.0 °C 3:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 20.0 °C 7:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 21.0 °C 6:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 22.0 °C 5:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 24.0 °C 5:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 27.0 °C 4:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 29.0 °C 3:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 20.0 °C 8:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 21.0 °C 7:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 22.0 °C 6:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 24.0 °C 5:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 27.0 °C 4:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 29.0 °C 4:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 20.0 °C 9:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 21.0 °C 8:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 22.0 °C 6:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 24.0 °C 6:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 27.0 °C 5:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 29.0 °C 4:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 20.0 °C 10:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 21.0 °C 9:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 22.0 °C 7:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 24.0 °C 7:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 27.0 °C 6:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 29.0 °C 5:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 20.0 °C 12:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 21.0 °C 10:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 22.0 °C 8:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 24.0 °C 8:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 27.0 °C 6:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 29.0 °C 5:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 20.0 °C 7:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 21.0 °C 6:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 22.0 °C 5:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 24.0 °C 5:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 27.0 °C 4:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 400 pull 3 stops 29.0 °C 3:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 20.0 °C 8:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 21.0 °C 7:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 22.0 °C 6:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 24.0 °C 5:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 27.0 °C 4:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 800 pull 2 stops 29.0 °C 4:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 20.0 °C 9:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 21.0 °C 8:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 22.0 °C 6:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 24.0 °C 6:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 27.0 °C 5:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 1600 pull 1 stop 29.0 °C 4:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 20.0 °C 10:30 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 21.0 °C 9:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 22.0 °C 7:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 24.0 °C 7:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 27.0 °C 6:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 3200 29.0 °C 5:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 20.0 °C 12:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 21.0 °C 10:15 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 22.0 °C 8:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 24.0 °C 8:00 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 27.0 °C 6:45 —
Verified Datasheet Report
T-Max P3200 Dilution B (1+31) 6400 push 1 stop 29.0 °C 5:45 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 18.0 °C 6:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 20.0 °C 5:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 21.0 °C 5:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 22.0 °C 4:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 24.0 °C 4:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 18.0 °C 4:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 20.0 °C 4:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 21.0 °C 4:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 22.0 °C 3:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 24.0 °C 3:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 18.0 °C 5:15 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 20.0 °C 4:45 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 21.0 °C 4:15 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 22.0 °C 4:00 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 24.0 °C 3:30 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 18.0 °C 3:15 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 20.0 °C 3:00 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 21.0 °C 2:45 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 22.0 °C 2:30 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 24.0 °C 2:15 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 18.0 °C 5:15 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 20.0 °C 4:45 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 21.0 °C 4:15 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 22.0 °C 4:00 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 24.0 °C 3:30 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 18.0 °C 3:45 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 20.0 °C 3:15 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 21.0 °C 3:00 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 22.0 °C 2:45 —
Verified Datasheet Report
Tri-X Dilution B (1+31) 320 24.0 °C 2:30 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 18.0 °C 4:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 20.0 °C 3:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 21.0 °C 3:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 22.0 °C 3:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 24.0 °C 2:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 18.0 °C 4:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 20.0 °C 3:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 21.0 °C 3:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 22.0 °C 3:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 24.0 °C 2:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 18.0 °C 4:00 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 20.0 °C 3:30 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 21.0 °C 3:00 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 22.0 °C 2:45 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 24.0 °C 2:30 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 18.0 °C 4:00 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 20.0 °C 3:30 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 21.0 °C 3:00 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 22.0 °C 2:45 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 24.0 °C 2:30 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 18.0 °C 4:00 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 20.0 °C 3:30 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 21.0 °C 3:00 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 22.0 °C 2:45 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 24.0 °C 2:30 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 18.0 °C 4:00 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 20.0 °C 3:30 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 21.0 °C 3:00 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 22.0 °C 2:45 —
Verified Datasheet Report
Plus-X Pan Dilution B (1+31) 125 24.0 °C 2:30 —
Verified Datasheet Report
Verichrome Pan Dilution B (1+31) 125 push 0.75 stops 18.0 °C 8:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Verichrome Pan Dilution B (1+31) 125 push 0.75 stops 20.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Verichrome Pan Dilution B (1+31) 125 push 0.75 stops 21.0 °C 6:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Verichrome Pan Dilution B (1+31) 125 push 0.75 stops 22.0 °C 5:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Verichrome Pan Dilution B (1+31) 125 push 0.75 stops 24.0 °C 4:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Verichrome Pan Dilution B (1+31) 125 push 0.75 stops 18.0 °C 6:00 —
Verified Datasheet Report
Verichrome Pan Dilution B (1+31) 125 push 0.75 stops 20.0 °C 5:00 —
Verified Datasheet Report
Verichrome Pan Dilution B (1+31) 125 push 0.75 stops 21.0 °C 4:30 —
Verified Datasheet Report
Verichrome Pan Dilution B (1+31) 125 push 0.75 stops 22.0 °C 4:00 —
Verified Datasheet Report
Ektapan Dilution A (1+15) 100 18.0 °C 4:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Ektapan Dilution A (1+15) 100 20.0 °C 3:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Ektapan Dilution A (1+15) 100 21.0 °C 3:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Ektapan Dilution A (1+15) 100 22.0 °C 3:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Ektapan Dilution A (1+15) 100 24.0 °C 2:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Ektapan Dilution B (1+31) 100 18.0 °C 7:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Ektapan Dilution B (1+31) 100 20.0 °C 6:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Ektapan Dilution B (1+31) 100 21.0 °C 5:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Ektapan Dilution B (1+31) 100 22.0 °C 5:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Ektapan Dilution B (1+31) 100 24.0 °C 4:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
Ektapan Dilution A (1+15) 100 18.0 °C 3:15 —
Verified Datasheet Report
Ektapan Dilution A (1+15) 100 20.0 °C 3:00 —
Verified Datasheet Report
Ektapan Dilution A (1+15) 100 21.0 °C 2:45 —
Verified Datasheet Report
Ektapan Dilution A (1+15) 100 22.0 °C 2:30 —
Verified Datasheet Report
Ektapan Dilution A (1+15) 100 24.0 °C 2:15 —
Verified Datasheet Report
Ektapan Dilution B (1+31) 100 18.0 °C 5:00 —
Verified Datasheet Report
Ektapan Dilution B (1+31) 100 20.0 °C 4:30 —
Verified Datasheet Report
Ektapan Dilution B (1+31) 100 21.0 °C 4:15 —
Verified Datasheet Report
Ektapan Dilution B (1+31) 100 22.0 °C 4:00 —
Verified Datasheet Report
Ektapan Dilution B (1+31) 100 24.0 °C 3:30 —
Verified Datasheet Report
RPX 25 Dilution B (1+31) 25 20.0 °C 5:00 —
Verified Datasheet Report
RPX 100 Dilution B (1+31) 100 20.0 °C 8:00 —
Verified Datasheet Report
RPX 400 Dilution B (1+31) 400 20.0 °C 6:00 —
Verified Datasheet Report
Retro 80S Dilution B (1+31) 80 20.0 °C 8:00 —
Verified Datasheet Report
Retro 400S Dilution B (1+31) 400 20.0 °C 10:00 —
Verified Datasheet Report
SuperPan 200 Dilution B (1+31) 200 20.0 °C 8:00 —
Verified Datasheet Report
Infrared 400 Dilution B (1+31) 400 20.0 °C 5:00 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 18.0 °C 7:00 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 20.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 21.0 °C 5:45 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 22.0 °C 5:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 24.0 °C 5:00 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 18.0 °C 7:00 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 20.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 21.0 °C 5:45 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 22.0 °C 5:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 24.0 °C 5:00 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 18.0 °C 7:00 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 20.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 21.0 °C 5:45 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 22.0 °C 5:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 24.0 °C 5:00 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 18.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 20.0 °C 5:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 21.0 °C 5:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 22.0 °C 4:45 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 24.0 °C 4:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 18.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 20.0 °C 5:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 21.0 °C 5:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 22.0 °C 4:45 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 24.0 °C 4:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 18.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 20.0 °C 5:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 21.0 °C 5:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 22.0 °C 4:45 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 24.0 °C 4:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 18.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 20.0 °C 5:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 21.0 °C 5:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 22.0 °C 4:45 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 24.0 °C 4:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 18.0 °C 6:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 20.0 °C 5:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 21.0 °C 5:15 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 22.0 °C 4:45 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 24.0 °C 4:30 —
Verified Datasheet Report
T-Max 400 Dilution B (1+31) 400 24.0 °C 4:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 18.0 °C 5:00 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 20.0 °C 4:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 21.0 °C 4:00 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 22.0 °C 3:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 24.0 °C 3:00 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 18.0 °C 5:00 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 20.0 °C 4:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 21.0 °C 4:00 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 22.0 °C 3:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 24.0 °C 3:00 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 18.0 °C 4:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 20.0 °C 3:45 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 21.0 °C 3:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 22.0 °C 3:00 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 24.0 °C 2:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 18.0 °C 4:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 20.0 °C 3:45 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 21.0 °C 3:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 22.0 °C 3:00 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 24.0 °C 2:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 18.0 °C 4:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 20.0 °C 3:45 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 21.0 °C 3:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 22.0 °C 3:00 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 24.0 °C 2:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 18.0 °C 4:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 20.0 °C 3:45 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 21.0 °C 3:30 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 22.0 °C 3:00 —
Verified Datasheet Report
Tri-X 400 Dilution B (1+31) 400 24.0 °C 2:30 —
Verified Datasheet Report

Reuse

Checked 21 October 2026

Kodak says Kodak HC-110 may be used for more than one film. It can also be replenished.

  • Dilution A (1+15) may be reused
  • Dilution B (1+31) may be reused
  • Dilution E (1+47) may be reused
  • Dilution D (1+39) may be reused
  • Dilution F (1+79) use once

The maker doesn’t publish a rule for lengthening the time, so the calculator makes no correction.

Capacity, as the maker states it: Tank, without replenishment, per gallon (8x10-inch sheets or equivalent): A 40, B 20, C 30, D 15, E 10, F not recommended.

It can be used for replenished and non-replenished systems. Use KODAK PROFESSIONAL HC-110 Developer Replenisher to replenish. ... Discard the developer after processing the number of sheets (or equivalent) listed below. ... Replenish tank solutions ... discard the tank solution when you have: Replenished the solution for two weeks; Added an amount of replenisher that equals the original volume of the working solution; or Processed fifty 20.3 x 25.4 cm sheets per litre (two hundred 8 x 10-inch sheets [or equivalent] per gallon) of developer.

KODAK PROFESSIONAL HC-110 Developer (KODAK Publication J-24, October 2002, major revision 10-02, 8 pp.) ↗

Dilutions

  • Dilution A (1+15) 1 + 15 water
  • Dilution B (1+31) 1 + 31 water
  • Dilution E (1+47) 1 + 47 water
  • Dilution H (1+63) 1 + 63 water
  • Dilution D (1+39) 1 + 39 water
  • Dilution F (1+79) 1 + 79 water
  • 1+49 1 + 49 water

Link to this page

Specification

Type
B&W developer
Form
Liquid concentrate
Capacity rolls per litre
—
Shelf life, unopened
—
Shelf life, opened
—

A dash means the figure has not been read off the maker’s sheet. A guess here would produce wrong answers silently.

Help keep it right

Suggest a time or report a mistake.

Know a time for HC-110 that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.

0 reviews

Written by photographers, under their own profile — so you can see what they shoot before you weigh what they say.