- Developers
- HC-110
HC-110
Development times
| Film | Dilution | EI | Temp | Time | Agitation | Source |
|---|---|---|---|---|---|---|
| T-Max 400 | Dilution B (1+31) | 400 | 18.0 °C | 5:45 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 20.0 °C | 5:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 21.0 °C | 4:45 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 22.0 °C | 4:30 | — | |
| Pan F Plus | Dilution B (1+31) | 50 | 20.0 °C | 4:00 | Ilford — 4 inversions every 60 s | |
| FP4 Plus | Dilution A (1+15) | 125 | 20.0 °C | 4:30 | Ilford — 4 inversions every 60 s | |
| FP4 Plus | Dilution A (1+15) | 200 push 0.75 stops | 20.0 °C | 6:00 | Ilford — 4 inversions every 60 s | |
| FP4 Plus | Dilution B (1+31) | 50 pull 1.25 stops | 20.0 °C | 6:00 | Ilford — 4 inversions every 60 s | |
| FP4 Plus | Dilution B (1+31) | 125 | 20.0 °C | 9:00 | Ilford — 4 inversions every 60 s | |
| FP4 Plus | Dilution B (1+31) | 200 push 0.75 stops | 20.0 °C | 12:00 | Ilford — 4 inversions every 60 s | |
| Ilford Delta 100 Pro | Dilution B (1+31) | 50 pull 1 stop | 20.0 °C | 5:00 | Ilford — 4 inversions every 60 s | |
| Ilford Delta 100 Pro | Dilution B (1+31) | 100 | 20.0 °C | 6:00 | Ilford — 4 inversions every 60 s | |
| Ilford Delta 100 Pro | Dilution B (1+31) | 200 push 1 stop | 20.0 °C | 8:00 | Ilford — 4 inversions every 60 s | |
| Ilford HP5+ | Dilution A (1+15) | 400 | 20.0 °C | 2:30 | Ilford — 4 inversions every 60 s | |
| Ilford HP5+ | Dilution A (1+15) | 800 push 1 stop | 20.0 °C | 3:45 | Ilford — 4 inversions every 60 s | |
| Ilford HP5+ | Dilution A (1+15) | 1600 push 2 stops | 20.0 °C | 5:30 | Ilford — 4 inversions every 60 s | |
| Ilford HP5+ | Dilution A (1+15) | 3200 push 3 stops | 20.0 °C | 9:30 | Ilford — 4 inversions every 60 s | |
| Ilford HP5+ | Dilution B (1+31) | 400 | 20.0 °C | 5:00 | Ilford — 4 inversions every 60 s | |
| Ilford HP5+ | Dilution B (1+31) | 800 push 1 stop | 20.0 °C | 7:30 | Ilford — 4 inversions every 60 s | |
| Ilford HP5+ | Dilution B (1+31) | 1600 push 2 stops | 20.0 °C | 11:00 | Ilford — 4 inversions every 60 s | |
| SFX 200 | Dilution A (1+15) | 200 | 20.0 °C | 5:00 | Ilford — 4 inversions every 60 s | |
| SFX 200 | Dilution A (1+15) | 400 push 1 stop | 20.0 °C | 7:00 | Ilford — 4 inversions every 60 s | |
| SFX 200 | Dilution A (1+15) | 800 push 2 stops | 20.0 °C | 10:30 | Ilford — 4 inversions every 60 s | |
| SFX 200 | Dilution B (1+31) | 200 | 20.0 °C | 9:00 | Ilford — 4 inversions every 60 s | |
| SFX 200 | Dilution B (1+31) | 400 push 1 stop | 20.0 °C | 13:00 | Ilford — 4 inversions every 60 s | |
| SFX 200 | Dilution B (1+31) | 800 push 2 stops | 20.0 °C | 19:00 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution A (1+15) | 320 pull 0.25 stops | 20.0 °C | 4:00 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution A (1+15) | 800 push 1 stop | 20.0 °C | 5:30 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution A (1+15) | 1600 push 2 stops | 20.0 °C | 7:30 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution A (1+15) | 3200 push 3 stops | 20.0 °C | 13:00 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution B (1+31) | 200 pull 1 stop | 20.0 °C | 5:00 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution B (1+31) | 400 | 20.0 °C | 7:30 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution B (1+31) | 800 push 1 stop | 20.0 °C | 10:00 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 20.0 °C | 13:30 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution A (1+15) | 800 push 1 stop | 24.0 °C | 4:30 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution A (1+15) | 1600 push 2 stops | 24.0 °C | 5:30 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution A (1+15) | 3200 push 3 stops | 24.0 °C | 8:00 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution B (1+31) | 200 pull 1 stop | 24.0 °C | 4:00 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution B (1+31) | 400 | 24.0 °C | 5:00 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution B (1+31) | 800 push 1 stop | 24.0 °C | 7:00 | Ilford — 4 inversions every 60 s | |
| Delta 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 24.0 °C | 10:00 | Ilford — 4 inversions every 60 s | |
| CHS 100 II | Dilution B (1+31) | 100 | 20.0 °C | 5:30 | Kodak — 30 s initial, then 5 s every 30 s | |
| CHS 100 II | Dilution D (1+39) | 100 | 20.0 °C | 7:00 | Kodak — 30 s initial, then 5 s every 30 s | |
| CHS 100 II | Dilution E (1+47) | 100 | 20.0 °C | 9:00 | Kodak — 30 s initial, then 5 s every 30 s | |
| CHS 100 II | Dilution B (1+31) | 100 | 20.0 °C | 5:30 | Kodak — 30 s initial, then 5 s every 30 s | |
| CHS 100 II | Dilution D (1+39) | 100 | 20.0 °C | 7:00 | Kodak — 30 s initial, then 5 s every 30 s | |
| CHS 100 II | Dilution E (1+47) | 100 | 20.0 °C | 9:00 | Kodak — 30 s initial, then 5 s every 30 s | |
| Pancro 400 | Dilution B (1+31) | 400 | 20.0 °C | 9:00 | — | |
| Pancro 400 | Dilution B (1+31) | 400 | 21.0 °C | 8:20 | — | |
| Pancro 400 | Dilution B (1+31) | 400 | 22.0 °C | 7:40 | — | |
| Pancro 400 | Dilution B (1+31) | 400 | 24.0 °C | 6:30 | — | |
| 'P' | Dilution A (1+15) | 100 | 20.0 °C | 4:30 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 20.0 °C | 11:30 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 21.0 °C | 10:15 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 22.0 °C | 9:15 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 24.0 °C | 7:45 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 21.0 °C | 10:15 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 22.0 °C | 9:15 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 24.0 °C | 7:45 | — | |
| Fomapan 400 Action | Dilution B (1+31) | 400 | 20.0 °C | 6:30 | — | |
| Retropan 320 Soft | Dilution B (1+31) | 320 | 20.0 °C | 7:00 | — | |
| Retropan 320 Soft | Dilution B (1+31) | 640 push 1 stop | 20.0 °C | 11:00 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 400 | 18.0 °C | 6:00 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 400 | 20.0 °C | 5:00 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 400 | 22.0 °C | 4:15 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 400 | 24.0 °C | 3:30 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 400 | 26.0 °C | 3:00 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 800 push 1 stop | 18.0 °C | 8:30 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 800 push 1 stop | 20.0 °C | 7:15 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 800 push 1 stop | 22.0 °C | 6:00 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 800 push 1 stop | 24.0 °C | 5:00 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 800 push 1 stop | 26.0 °C | 4:15 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 18.0 °C | 14:30 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 20.0 °C | 12:00 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 22.0 °C | 10:00 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 24.0 °C | 8:15 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 26.0 °C | 7:00 | — | |
| 'Y' | Dilution A (1+15) | 100 | 20.0 °C | 4:30 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 400 | 18.0 °C | 6:15 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 400 | 20.0 °C | 5:15 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 400 | 22.0 °C | 4:30 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 400 | 24.0 °C | 3:45 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 400 | 26.0 °C | 3:15 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 800 push 1 stop | 18.0 °C | 9:00 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 800 push 1 stop | 20.0 °C | 7:30 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 800 push 1 stop | 22.0 °C | 6:15 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 800 push 1 stop | 24.0 °C | 5:15 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 800 push 1 stop | 26.0 °C | 4:30 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 18.0 °C | 14:30 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 20.0 °C | 12:00 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 22.0 °C | 10:00 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 24.0 °C | 8:30 | — | |
| Neopan 400 Professional | Dilution B (1+31) | 1600 push 2 stops | 26.0 °C | 7:15 | — | |
| 'V' | Dilution A (1+15) | 100 | 20.0 °C | 4:30 | — | |
| Neopan 1600 Professional | Dilution B (1+31) | 800 pull 1 stop | 18.0 °C | 5:30 | — | |
| Neopan 1600 Professional | Dilution B (1+31) | 800 pull 1 stop | 20.0 °C | 4:45 | — | |
| Neopan 1600 Professional | Dilution B (1+31) | 800 pull 1 stop | 22.0 °C | 4:00 | — | |
| Neopan 1600 Professional | Dilution B (1+31) | 800 pull 1 stop | 24.0 °C | 3:30 | — | |
| Neopan 1600 Professional | Dilution B (1+31) | 1600 | 18.0 °C | 8:15 | — | |
| Neopan 1600 Professional | Dilution B (1+31) | 1600 | 20.0 °C | 7:00 | — | |
| Neopan 1600 Professional | Dilution B (1+31) | 1600 | 22.0 °C | 5:45 | — | |
| Neopan 1600 Professional | Dilution B (1+31) | 1600 | 24.0 °C | 5:00 | — | |
| Neopan 1600 Professional | Dilution B (1+31) | 1600 | 26.0 °C | 4:15 | — | |
| Pan 100 | Dilution A (1+15) | 100 | 20.0 °C | 4:00 | Ilford — 4 inversions every 60 s | |
| Pan 100 | Dilution A (1+15) | 200 push 1 stop | 20.0 °C | 5:00 | Ilford — 4 inversions every 60 s | |
| Pan 100 | Dilution B (1+31) | 50 pull 1 stop | 20.0 °C | 6:00 | Ilford — 4 inversions every 60 s | |
| Pan 100 | Dilution B (1+31) | 100 | 20.0 °C | 8:00 | Ilford — 4 inversions every 60 s | |
| Pan 100 | Dilution B (1+31) | 200 push 1 stop | 20.0 °C | 9:00 | Ilford — 4 inversions every 60 s | |
| Pan 400 | Dilution A (1+15) | 400 | 20.0 °C | 3:00 | Ilford — 4 inversions every 60 s | |
| Pan 400 | Dilution A (1+15) | 800 push 1 stop | 20.0 °C | 5:00 | Ilford — 4 inversions every 60 s | |
| Pan 400 | Dilution A (1+15) | 1600 push 2 stops | 20.0 °C | 7:00 | Ilford — 4 inversions every 60 s | |
| Pan 400 | Dilution B (1+31) | 400 | 20.0 °C | 6:00 | Ilford — 4 inversions every 60 s | |
| Pan 400 | Dilution B (1+31) | 800 push 1 stop | 20.0 °C | 9:00 | Ilford — 4 inversions every 60 s | |
| Pan 400 | Dilution B (1+31) | 1600 push 2 stops | 20.0 °C | 14:00 | Ilford — 4 inversions every 60 s | |
| Lady Grey 400 | Dilution B (1+31) | 400 | 20.0 °C | 5:30 | — | |
| Earl Grey | Dilution B (1+31) | 100 | 20.0 °C | 6:30 | — | |
| Berlin 400 | Dilution B (1+31) | 400 | 20.0 °C | 8:07 | — | |
| Fantome Kino | Dilution B (1+31) | 8 | 20.0 °C | 7:00 | — | |
| Babylon Kino | Dilution B (1+31) | 13 | 20.0 °C | 8:30 | — | |
| Orca | Dilution B (1+31) | 100 | 20.0 °C | 8:07 | — | |
| Agent Shadow | Dilution B (1+31) | 400 | 20.0 °C | 5:00 | — | |
| Agent Shadow | Dilution E (1+47) | 400 | 20.0 °C | 8:00 | — | |
| Agent Shadow | Dilution E (1+47) | 800 push 1 stop | 20.0 °C | 13:00 | — | |
| P30 | Dilution H (1+63) | 80 | 20.0 °C | 12:00 | — | |
| P30 | Dilution B (1+31) | 80 | 20.0 °C | 5:00 | — | |
| 'F' | Dilution A (1+15) | 100 | 20.0 °C | 4:30 | — | |
| 'K' | Dilution B (1+31) | 100 | 24.0 °C | 5:00 | — | |
| WolfMan | Dilution H (1+63) | 100 | 20.0 °C | 12:00 | — | |
| S25 | Dilution F (1+79) | 25 | 20.0 °C | 10:00 | — | |
| U200 | Dilution B (1+31) | 200 | 20.0 °C | 4:30 | — | |
| U400 | Dilution B (1+31) | 400 | 20.0 °C | 5:00 | — | |
| WolfMan | Dilution B (1+31) | 100 | 20.0 °C | 6:00 | — | |
| WolfMan | Dilution H (1+63) | 100 | 20.0 °C | 12:00 | — | |
| WolfMan | Dilution B (1+31) | 100 | 20.0 °C | 6:00 | — | |
| Frankenstein | Dilution B (1+31) | 200 | 20.0 °C | 4:00 | — | |
| Frankenstein | Dilution H (1+63) | 200 | 20.0 °C | 9:00 | — | |
| Frankenstein | Dilution B (1+31) | 200 | 20.0 °C | 4:00 | — | |
| Frankenstein | Dilution H (1+63) | 200 | 20.0 °C | 9:00 | — | |
| Frankenstein | Dilution B (1+31) | 200 | 20.0 °C | 4:00 | — | |
| Frankenstein | Dilution H (1+63) | 200 | 20.0 °C | 9:00 | — | |
| Eastman Kodak Hi-Fi 2374 | Dilution H (1+63) | 50 | 20.0 °C | 7:30 | — | |
| Eastman Kodak Hi-Fi 2374 | Dilution H (1+63) | 100 push 1 stop | 20.0 °C | 8:30 | — | |
| BW IR | Dilution B (1+31) | 200 | 20.0 °C | 7:00 | — | |
| Sonic 25 BW Film | Dilution H (1+63) | 25 | 20.0 °C | 11:00 | — | |
| Xtreme 100 | Dilution B (1+31) | 100 | 20.0 °C | 8:30 | — | |
| Xtreme 400 | Dilution B (1+31) | 400 | 20.0 °C | 5:00 | — | |
| X FILM 320 Pro | 1+49 | 200 pull 0.75 stops | 20.0 °C | 10:30 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 18.0 °C | 7:30 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 20.0 °C | 6:30 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 21.0 °C | 6:00 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 22.0 °C | 5:15 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 24.0 °C | 4:30 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 18.0 °C | 7:30 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 20.0 °C | 6:30 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 21.0 °C | 6:00 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 22.0 °C | 5:15 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 24.0 °C | 4:30 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 18.0 °C | 7:30 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 20.0 °C | 6:30 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 21.0 °C | 6:00 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 22.0 °C | 5:15 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 24.0 °C | 4:30 | Kodak — large tank, 1 min intervals | |
| T-Max 100 | Dilution B (1+31) | 100 | 18.0 °C | 7:00 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 20.0 °C | 5:45 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 21.0 °C | 5:15 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 22.0 °C | 4:45 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 24.0 °C | 4:00 | — | |
| T-Max 100 | Dilution B (1+31) | 200 push 1 stop | 20.0 °C | 5:45 | — | |
| T-Max 100 | Dilution B (1+31) | 200 push 1 stop | 24.0 °C | 4:00 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 18.0 °C | 7:00 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 20.0 °C | 5:45 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 21.0 °C | 5:15 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 22.0 °C | 4:45 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 24.0 °C | 4:00 | — | |
| T-Max 100 | Dilution B (1+31) | 200 push 1 stop | 20.0 °C | 5:45 | — | |
| T-Max 100 | Dilution B (1+31) | 200 push 1 stop | 24.0 °C | 4:00 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 20.0 °C | 11:30 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 18.0 °C | 7:00 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 20.0 °C | 5:45 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 21.0 °C | 5:15 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 22.0 °C | 4:45 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 24.0 °C | 4:00 | — | |
| T-Max 100 | Dilution B (1+31) | 200 push 1 stop | 20.0 °C | 5:45 | — | |
| T-Max 100 | Dilution B (1+31) | 200 push 1 stop | 24.0 °C | 4:00 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 20.0 °C | 11:30 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 21.0 °C | 10:15 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 22.0 °C | 9:15 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 24.0 °C | 7:45 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 18.0 °C | 6:30 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 20.0 °C | 6:00 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 21.0 °C | 5:30 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 22.0 °C | 5:00 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 24.0 °C | 4:00 | — | |
| T-Max 100 | Dilution B (1+31) | 200 push 1 stop | 20.0 °C | 6:00 | — | |
| T-Max 100 | Dilution B (1+31) | 200 push 1 stop | 24.0 °C | 4:00 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 20.0 °C | 11:30 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 24.0 °C | 7:45 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 18.0 °C | 6:30 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 20.0 °C | 6:00 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 21.0 °C | 5:30 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 22.0 °C | 5:00 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 24.0 °C | 4:00 | — | |
| T-Max 100 | Dilution B (1+31) | 200 push 1 stop | 20.0 °C | 6:00 | — | |
| T-Max 100 | Dilution B (1+31) | 200 push 1 stop | 24.0 °C | 4:00 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 20.0 °C | 11:30 | — | |
| T-Max 100 | Dilution B (1+31) | 400 push 2 stops | 24.0 °C | 7:45 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 18.0 °C | 6:15 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 20.0 °C | 5:30 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 21.0 °C | 4:45 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 22.0 °C | 4:30 | — | |
| T-Max 100 | Dilution B (1+31) | 100 | 24.0 °C | 3:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 20.0 °C | 7:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 21.0 °C | 6:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 22.0 °C | 5:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 24.0 °C | 5:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 27.0 °C | 4:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 29.0 °C | 3:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 20.0 °C | 8:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 21.0 °C | 7:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 22.0 °C | 6:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 24.0 °C | 5:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 27.0 °C | 4:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 29.0 °C | 4:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 20.0 °C | 9:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 21.0 °C | 8:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 22.0 °C | 6:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 24.0 °C | 6:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 27.0 °C | 5:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 29.0 °C | 4:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 20.0 °C | 10:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 21.0 °C | 9:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 22.0 °C | 7:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 24.0 °C | 7:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 27.0 °C | 6:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 29.0 °C | 5:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 20.0 °C | 12:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 21.0 °C | 10:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 22.0 °C | 8:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 24.0 °C | 8:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 27.0 °C | 6:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 29.0 °C | 5:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 20.0 °C | 7:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 21.0 °C | 6:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 22.0 °C | 5:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 24.0 °C | 5:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 27.0 °C | 4:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 400 pull 3 stops | 29.0 °C | 3:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 20.0 °C | 8:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 21.0 °C | 7:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 22.0 °C | 6:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 24.0 °C | 5:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 27.0 °C | 4:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 800 pull 2 stops | 29.0 °C | 4:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 20.0 °C | 9:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 21.0 °C | 8:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 22.0 °C | 6:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 24.0 °C | 6:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 27.0 °C | 5:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 1600 pull 1 stop | 29.0 °C | 4:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 20.0 °C | 10:30 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 21.0 °C | 9:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 22.0 °C | 7:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 24.0 °C | 7:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 27.0 °C | 6:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 3200 | 29.0 °C | 5:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 20.0 °C | 12:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 21.0 °C | 10:15 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 22.0 °C | 8:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 24.0 °C | 8:00 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 27.0 °C | 6:45 | — | |
| T-Max P3200 | Dilution B (1+31) | 6400 push 1 stop | 29.0 °C | 5:45 | — | |
| Tri-X | Dilution B (1+31) | 320 | 18.0 °C | 6:15 | Kodak — large tank, 1 min intervals | |
| Tri-X | Dilution B (1+31) | 320 | 20.0 °C | 5:30 | Kodak — large tank, 1 min intervals | |
| Tri-X | Dilution B (1+31) | 320 | 21.0 °C | 5:00 | Kodak — large tank, 1 min intervals | |
| Tri-X | Dilution B (1+31) | 320 | 22.0 °C | 4:30 | Kodak — large tank, 1 min intervals | |
| Tri-X | Dilution B (1+31) | 320 | 24.0 °C | 4:00 | Kodak — large tank, 1 min intervals | |
| Tri-X | Dilution B (1+31) | 320 | 18.0 °C | 4:45 | Kodak — large tank, 1 min intervals | |
| Tri-X | Dilution B (1+31) | 320 | 20.0 °C | 4:15 | Kodak — large tank, 1 min intervals | |
| Tri-X | Dilution B (1+31) | 320 | 21.0 °C | 4:00 | Kodak — large tank, 1 min intervals | |
| Tri-X | Dilution B (1+31) | 320 | 22.0 °C | 3:30 | Kodak — large tank, 1 min intervals | |
| Tri-X | Dilution B (1+31) | 320 | 24.0 °C | 3:00 | Kodak — large tank, 1 min intervals | |
| Tri-X | Dilution B (1+31) | 320 | 18.0 °C | 5:15 | — | |
| Tri-X | Dilution B (1+31) | 320 | 20.0 °C | 4:45 | — | |
| Tri-X | Dilution B (1+31) | 320 | 21.0 °C | 4:15 | — | |
| Tri-X | Dilution B (1+31) | 320 | 22.0 °C | 4:00 | — | |
| Tri-X | Dilution B (1+31) | 320 | 24.0 °C | 3:30 | — | |
| Tri-X | Dilution B (1+31) | 320 | 18.0 °C | 3:15 | — | |
| Tri-X | Dilution B (1+31) | 320 | 20.0 °C | 3:00 | — | |
| Tri-X | Dilution B (1+31) | 320 | 21.0 °C | 2:45 | — | |
| Tri-X | Dilution B (1+31) | 320 | 22.0 °C | 2:30 | — | |
| Tri-X | Dilution B (1+31) | 320 | 24.0 °C | 2:15 | — | |
| Tri-X | Dilution B (1+31) | 320 | 18.0 °C | 5:15 | — | |
| Tri-X | Dilution B (1+31) | 320 | 20.0 °C | 4:45 | — | |
| Tri-X | Dilution B (1+31) | 320 | 21.0 °C | 4:15 | — | |
| Tri-X | Dilution B (1+31) | 320 | 22.0 °C | 4:00 | — | |
| Tri-X | Dilution B (1+31) | 320 | 24.0 °C | 3:30 | — | |
| Tri-X | Dilution B (1+31) | 320 | 18.0 °C | 3:45 | — | |
| Tri-X | Dilution B (1+31) | 320 | 20.0 °C | 3:15 | — | |
| Tri-X | Dilution B (1+31) | 320 | 21.0 °C | 3:00 | — | |
| Tri-X | Dilution B (1+31) | 320 | 22.0 °C | 2:45 | — | |
| Tri-X | Dilution B (1+31) | 320 | 24.0 °C | 2:30 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 18.0 °C | 4:30 | Kodak — large tank, 1 min intervals | |
| Plus-X Pan | Dilution B (1+31) | 125 | 20.0 °C | 3:45 | Kodak — large tank, 1 min intervals | |
| Plus-X Pan | Dilution B (1+31) | 125 | 21.0 °C | 3:30 | Kodak — large tank, 1 min intervals | |
| Plus-X Pan | Dilution B (1+31) | 125 | 22.0 °C | 3:15 | Kodak — large tank, 1 min intervals | |
| Plus-X Pan | Dilution B (1+31) | 125 | 24.0 °C | 2:45 | Kodak — large tank, 1 min intervals | |
| Plus-X Pan | Dilution B (1+31) | 125 | 18.0 °C | 4:30 | Kodak — large tank, 1 min intervals | |
| Plus-X Pan | Dilution B (1+31) | 125 | 20.0 °C | 3:45 | Kodak — large tank, 1 min intervals | |
| Plus-X Pan | Dilution B (1+31) | 125 | 21.0 °C | 3:30 | Kodak — large tank, 1 min intervals | |
| Plus-X Pan | Dilution B (1+31) | 125 | 22.0 °C | 3:15 | Kodak — large tank, 1 min intervals | |
| Plus-X Pan | Dilution B (1+31) | 125 | 24.0 °C | 2:45 | Kodak — large tank, 1 min intervals | |
| Plus-X Pan | Dilution B (1+31) | 125 | 18.0 °C | 4:00 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 20.0 °C | 3:30 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 21.0 °C | 3:00 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 22.0 °C | 2:45 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 24.0 °C | 2:30 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 18.0 °C | 4:00 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 20.0 °C | 3:30 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 21.0 °C | 3:00 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 22.0 °C | 2:45 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 24.0 °C | 2:30 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 18.0 °C | 4:00 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 20.0 °C | 3:30 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 21.0 °C | 3:00 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 22.0 °C | 2:45 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 24.0 °C | 2:30 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 18.0 °C | 4:00 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 20.0 °C | 3:30 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 21.0 °C | 3:00 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 22.0 °C | 2:45 | — | |
| Plus-X Pan | Dilution B (1+31) | 125 | 24.0 °C | 2:30 | — | |
| Verichrome Pan | Dilution B (1+31) | 125 push 0.75 stops | 18.0 °C | 8:00 | Kodak — large tank, 1 min intervals | |
| Verichrome Pan | Dilution B (1+31) | 125 push 0.75 stops | 20.0 °C | 6:30 | Kodak — large tank, 1 min intervals | |
| Verichrome Pan | Dilution B (1+31) | 125 push 0.75 stops | 21.0 °C | 6:00 | Kodak — large tank, 1 min intervals | |
| Verichrome Pan | Dilution B (1+31) | 125 push 0.75 stops | 22.0 °C | 5:30 | Kodak — large tank, 1 min intervals | |
| Verichrome Pan | Dilution B (1+31) | 125 push 0.75 stops | 24.0 °C | 4:30 | Kodak — large tank, 1 min intervals | |
| Verichrome Pan | Dilution B (1+31) | 125 push 0.75 stops | 18.0 °C | 6:00 | — | |
| Verichrome Pan | Dilution B (1+31) | 125 push 0.75 stops | 20.0 °C | 5:00 | — | |
| Verichrome Pan | Dilution B (1+31) | 125 push 0.75 stops | 21.0 °C | 4:30 | — | |
| Verichrome Pan | Dilution B (1+31) | 125 push 0.75 stops | 22.0 °C | 4:00 | — | |
| Ektapan | Dilution A (1+15) | 100 | 18.0 °C | 4:00 | Kodak — large tank, 1 min intervals | |
| Ektapan | Dilution A (1+15) | 100 | 20.0 °C | 3:45 | Kodak — large tank, 1 min intervals | |
| Ektapan | Dilution A (1+15) | 100 | 21.0 °C | 3:15 | Kodak — large tank, 1 min intervals | |
| Ektapan | Dilution A (1+15) | 100 | 22.0 °C | 3:00 | Kodak — large tank, 1 min intervals | |
| Ektapan | Dilution A (1+15) | 100 | 24.0 °C | 2:45 | Kodak — large tank, 1 min intervals | |
| Ektapan | Dilution B (1+31) | 100 | 18.0 °C | 7:00 | Kodak — large tank, 1 min intervals | |
| Ektapan | Dilution B (1+31) | 100 | 20.0 °C | 6:00 | Kodak — large tank, 1 min intervals | |
| Ektapan | Dilution B (1+31) | 100 | 21.0 °C | 5:30 | Kodak — large tank, 1 min intervals | |
| Ektapan | Dilution B (1+31) | 100 | 22.0 °C | 5:00 | Kodak — large tank, 1 min intervals | |
| Ektapan | Dilution B (1+31) | 100 | 24.0 °C | 4:15 | Kodak — large tank, 1 min intervals | |
| Ektapan | Dilution A (1+15) | 100 | 18.0 °C | 3:15 | — | |
| Ektapan | Dilution A (1+15) | 100 | 20.0 °C | 3:00 | — | |
| Ektapan | Dilution A (1+15) | 100 | 21.0 °C | 2:45 | — | |
| Ektapan | Dilution A (1+15) | 100 | 22.0 °C | 2:30 | — | |
| Ektapan | Dilution A (1+15) | 100 | 24.0 °C | 2:15 | — | |
| Ektapan | Dilution B (1+31) | 100 | 18.0 °C | 5:00 | — | |
| Ektapan | Dilution B (1+31) | 100 | 20.0 °C | 4:30 | — | |
| Ektapan | Dilution B (1+31) | 100 | 21.0 °C | 4:15 | — | |
| Ektapan | Dilution B (1+31) | 100 | 22.0 °C | 4:00 | — | |
| Ektapan | Dilution B (1+31) | 100 | 24.0 °C | 3:30 | — | |
| RPX 25 | Dilution B (1+31) | 25 | 20.0 °C | 5:00 | — | |
| RPX 100 | Dilution B (1+31) | 100 | 20.0 °C | 8:00 | — | |
| RPX 400 | Dilution B (1+31) | 400 | 20.0 °C | 6:00 | — | |
| Retro 80S | Dilution B (1+31) | 80 | 20.0 °C | 8:00 | — | |
| Retro 400S | Dilution B (1+31) | 400 | 20.0 °C | 10:00 | — | |
| SuperPan 200 | Dilution B (1+31) | 200 | 20.0 °C | 8:00 | — | |
| Infrared 400 | Dilution B (1+31) | 400 | 20.0 °C | 5:00 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 18.0 °C | 7:00 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 20.0 °C | 6:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 21.0 °C | 5:45 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 22.0 °C | 5:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 24.0 °C | 5:00 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 18.0 °C | 7:00 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 20.0 °C | 6:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 21.0 °C | 5:45 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 22.0 °C | 5:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 24.0 °C | 5:00 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 18.0 °C | 7:00 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 20.0 °C | 6:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 21.0 °C | 5:45 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 22.0 °C | 5:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 24.0 °C | 5:00 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 18.0 °C | 6:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 20.0 °C | 5:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 21.0 °C | 5:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 22.0 °C | 4:45 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 24.0 °C | 4:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 18.0 °C | 6:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 20.0 °C | 5:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 21.0 °C | 5:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 22.0 °C | 4:45 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 24.0 °C | 4:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 18.0 °C | 6:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 20.0 °C | 5:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 21.0 °C | 5:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 22.0 °C | 4:45 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 24.0 °C | 4:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 18.0 °C | 6:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 20.0 °C | 5:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 21.0 °C | 5:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 22.0 °C | 4:45 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 24.0 °C | 4:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 18.0 °C | 6:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 20.0 °C | 5:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 21.0 °C | 5:15 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 22.0 °C | 4:45 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 24.0 °C | 4:30 | — | |
| T-Max 400 | Dilution B (1+31) | 400 | 24.0 °C | 4:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 18.0 °C | 5:00 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 20.0 °C | 4:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 21.0 °C | 4:00 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 22.0 °C | 3:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 24.0 °C | 3:00 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 18.0 °C | 5:00 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 20.0 °C | 4:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 21.0 °C | 4:00 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 22.0 °C | 3:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 24.0 °C | 3:00 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 18.0 °C | 4:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 20.0 °C | 3:45 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 21.0 °C | 3:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 22.0 °C | 3:00 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 24.0 °C | 2:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 18.0 °C | 4:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 20.0 °C | 3:45 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 21.0 °C | 3:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 22.0 °C | 3:00 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 24.0 °C | 2:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 18.0 °C | 4:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 20.0 °C | 3:45 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 21.0 °C | 3:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 22.0 °C | 3:00 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 24.0 °C | 2:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 18.0 °C | 4:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 20.0 °C | 3:45 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 21.0 °C | 3:30 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 22.0 °C | 3:00 | — | |
| Tri-X 400 | Dilution B (1+31) | 400 | 24.0 °C | 2:30 | — |
Reuse
Checked 21 October 2026
Kodak says Kodak HC-110 may be used for more than one film. It can also be replenished.
- Dilution A (1+15) may be reused
- Dilution B (1+31) may be reused
- Dilution E (1+47) may be reused
- Dilution D (1+39) may be reused
- Dilution F (1+79) use once
The maker doesn’t publish a rule for lengthening the time, so the calculator makes no correction.
Capacity, as the maker states it: Tank, without replenishment, per gallon (8x10-inch sheets or equivalent): A 40, B 20, C 30, D 15, E 10, F not recommended.
It can be used for replenished and non-replenished systems. Use KODAK PROFESSIONAL HC-110 Developer Replenisher to replenish. ... Discard the developer after processing the number of sheets (or equivalent) listed below. ... Replenish tank solutions ... discard the tank solution when you have: Replenished the solution for two weeks; Added an amount of replenisher that equals the original volume of the working solution; or Processed fifty 20.3 x 25.4 cm sheets per litre (two hundred 8 x 10-inch sheets [or equivalent] per gallon) of developer.
Dilutions
- Dilution A (1+15) 1 + 15 water
- Dilution B (1+31) 1 + 31 water
- Dilution E (1+47) 1 + 47 water
- Dilution H (1+63) 1 + 63 water
- Dilution D (1+39) 1 + 39 water
- Dilution F (1+79) 1 + 79 water
- 1+49 1 + 49 water
Link to this page
Specification
- Type
- B&W developer
- Form
- Liquid concentrate
- Capacity rolls per litre
- —
- Shelf life, unopened
- —
- Shelf life, opened
- —
A dash means the figure has not been read off the maker’s sheet. A guess here would produce wrong answers silently.
Help keep it right
Suggest a time or report a mistake.
Know a time for HC-110 that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.
- Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
- Nothing goes up by itself. Every report is read by a person before anything on the page changes.
- No account needed. Your name and email are optional, and only to reply to you.
0 reviews
Written by photographers, under their own profile — so you can see what they shoot before you weigh what they say.