- Films
- Delta 400 Professional
- in Ilfotec LC29
Development times
Ilford Delta 400 Professional in Ilford Ilfotec LC29
22 published times at 1+19, 1+29, 1+9, rated at EI 200–3200, 20.0–24.0 °C. Each one is linked to the datasheet or chart it was read from.
Open in the calculator
Speed
EI 400
Dilution
1+19
Temperature
20.0 °C
Embed Show this time on your own site
The card shows the time, its source and a link back here. It sets no cookies and loads nothing from other sites. More options are in the API documentation.
Preview
Every published time
| Developer | Dilution | EI | Temp | Time | Agitation | Source |
|---|---|---|---|---|---|---|
| Ilfotec LC29 | 1+19 | 200 pull 1 stop | 20.0 °C | 5:00 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+29 | 200 pull 1 stop | 20.0 °C | 8:30 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+19 | 200 pull 1 stop | 24.0 °C | 4:00 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+29 | 200 pull 1 stop | 24.0 °C | 5:30 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+9 | 320 pull 0.25 stops | 20.0 °C | 4:00 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+19 | 400 | 20.0 °C | 7:30 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+29 | 400 | 20.0 °C | 11:30 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+19 | 400 | 24.0 °C | 5:00 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+29 | 400 | 24.0 °C | 7:30 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+9 | 800 push 1 stop | 20.0 °C | 5:30 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+19 | 800 push 1 stop | 20.0 °C | 10:00 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+29 | 800 push 1 stop | 20.0 °C | 17:00 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+9 | 800 push 1 stop | 24.0 °C | 4:30 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+19 | 800 push 1 stop | 24.0 °C | 7:00 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+29 | 800 push 1 stop | 24.0 °C | 11:00 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+9 | 1600 push 2 stops | 20.0 °C | 7:30 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+19 | 1600 push 2 stops | 20.0 °C | 13:30 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+9 | 1600 push 2 stops | 24.0 °C | 5:30 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+19 | 1600 push 2 stops | 24.0 °C | 10:00 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+29 | 1600 push 2 stops | 24.0 °C | 16:00 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+9 | 3200 push 3 stops | 20.0 °C | 13:00 | Ilford — 4 inversions every 60 s | |
| Ilfotec LC29 | 1+9 | 3200 push 3 stops | 24.0 °C | 8:00 | Ilford — 4 inversions every 60 s |
About the film
Ilford Delta 400 Professional ISO 400
Specification and all times ›
Delta 400 Professional in other developers
About the developer
Help keep it right
Suggest a time or report a mistake.
Know a time for Delta 400 Professional in Ilfotec LC29 that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.
- Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
- Nothing goes up by itself. Every report is read by a person before anything on the page changes.
- No account needed. Your name and email are optional, and only to reply to you.