- Films
- Delta 400 Professional
- in Perceptol
Development times
Ilford Delta 400 Professional in Ilford Perceptol
11 published times at stock, 1+1, 1+3, rated at EI 200–320, 20.0–24.0 °C. Each one is linked to the datasheet or chart it was read from.
Open in the calculator
Embed Show this time on your own site
The card shows the time, its source and a link back here. It sets no cookies and loads nothing from other sites. More options are in the API documentation.
Preview
Every published time
| Developer | Dilution | EI | Temp | Time | Agitation | Source |
|---|---|---|---|---|---|---|
| Perceptol | stock | 200 pull 1 stop | 20.0 °C | 10:00 | Ilford — 4 inversions every 60 s | |
| Perceptol | 1+1 | 200 pull 1 stop | 20.0 °C | 12:30 | Ilford — 4 inversions every 60 s | |
| Perceptol | 1+3 | 200 pull 1 stop | 20.0 °C | 18:30 | Ilford — 4 inversions every 60 s | |
| Perceptol | stock | 200 pull 1 stop | 24.0 °C | 7:00 | Ilford — 4 inversions every 60 s | |
| Perceptol | 1+1 | 200 pull 1 stop | 24.0 °C | 9:00 | Ilford — 4 inversions every 60 s | |
| Perceptol | 1+3 | 200 pull 1 stop | 24.0 °C | 14:30 | Ilford — 4 inversions every 60 s | |
| Perceptol | stock | 250 pull 0.75 stops | 20.0 °C | 12:00 | Ilford — 4 inversions every 60 s | |
| Perceptol | stock | 250 pull 0.75 stops | 24.0 °C | 9:00 | Ilford — 4 inversions every 60 s | |
| Perceptol | 1+1 | 320 pull 0.25 stops | 20.0 °C | 15:30 | Ilford — 4 inversions every 60 s | |
| Perceptol | 1+1 | 320 pull 0.25 stops | 24.0 °C | 11:30 | Ilford — 4 inversions every 60 s | |
| Perceptol | 1+3 | 320 pull 0.25 stops | 24.0 °C | 17:30 | Ilford — 4 inversions every 60 s |
About the film
Ilford Delta 400 Professional ISO 400
Specification and all times ›
Delta 400 Professional in other developers
About the developer
Ilford Perceptol
Dilutions and all films ›
Other films in Perceptol
Help keep it right
Suggest a time or report a mistake.
Know a time for Delta 400 Professional in Perceptol that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.