Skip to content

Eastman Kodak Company

T-Max 100

Nominal ISO 100
B&W negative B&W In production

Development times

Open in the calculator ›
Clear

Showing 267 of 442 published times.

Developer Dilution EI Temp Time Agitation Source
Perceptol stock 100 20.0 °C 12:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Perceptol 1+1 100 20.0 °C 13:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Perceptol 1+3 100 20.0 °C 19:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
ID-11 stock 100 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
ID-11 1+1 100 20.0 °C 11:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
ID-11 1+3 100 20.0 °C 16:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Microphen stock 100 20.0 °C 8:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Microphen 1+1 100 20.0 °C 11:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
Microphen 1+3 100 20.0 °C 16:00 Ilford — 4 inversions every 60 s
Unverified Datasheet Report
FX-39 Type II 1+9 100 20.0 °C 8:00 —
Verified Datasheet Report
Fomadon Excel W27 1+1 100 20.0 °C 9:00 —
Verified Datasheet Report
Fomadon Excel W27 stock 100 20.0 °C 7:00 —
Verified Datasheet Report
Fomadon LQN 1+10 100 20.0 °C 11:00 —
Verified Datasheet Report
Fomadon P 1+1 100 20.0 °C 18:00 —
Verified Datasheet Report
Fomadon P stock 100 20.0 °C 12:00 —
Verified Datasheet Report
Fomadon R09 1+50 100 20.0 °C 15:00 —
Verified Datasheet Report
D-76 stock 100 18.0 °C 7:30 —
Verified Datasheet Report
D-76 stock 100 20.0 °C 6:15 —
Verified Datasheet Report
D-76 stock 100 21.0 °C 5:45 —
Verified Datasheet Report
D-76 stock 100 22.0 °C 5:15 —
Verified Datasheet Report
D-76 stock 100 18.0 °C 7:30 —
Verified Datasheet Report
D-76 stock 100 20.0 °C 6:15 —
Verified Datasheet Report
D-76 stock 100 21.0 °C 5:45 —
Verified Datasheet Report
D-76 stock 100 22.0 °C 5:15 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:00 —
Verified Datasheet Report
T-Max RS 1+4 100 22.0 °C 6:45 —
Verified Datasheet Report
T-Max RS 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
D-76 stock 100 18.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 20.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 21.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 22.0 °C 5:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 24.0 °C 4:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 18.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 20.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 21.0 °C 6:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 22.0 °C 5:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 24.0 °C 4:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max Developer 1+4 100 20.0 °C 8:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max Developer 1+4 100 21.0 °C 8:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max Developer 1+4 100 22.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max Developer 1+4 100 24.0 °C 7:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 20.0 °C 8:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 21.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 22.0 °C 7:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 24.0 °C 7:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 18.0 °C 9:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 20.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 21.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 22.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 18.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 20.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+7 100 24.0 °C 8:30 —
Verified Datasheet Report
D-76 stock 100 21.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 22.0 °C 5:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 24.0 °C 4:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 18.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 20.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 21.0 °C 6:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 22.0 °C 5:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 24.0 °C 4:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max Developer 1+4 100 20.0 °C 8:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max Developer 1+4 100 21.0 °C 8:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max Developer 1+4 100 22.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max Developer 1+4 100 24.0 °C 7:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 20.0 °C 8:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 21.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 22.0 °C 7:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 24.0 °C 7:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 18.0 °C 9:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 20.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 21.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 22.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 18.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 20.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 21.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 22.0 °C 5:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 24.0 °C 4:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 18.0 °C 7:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 20.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 21.0 °C 6:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 22.0 °C 5:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 24.0 °C 4:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 20.0 °C 8:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 21.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 22.0 °C 7:45 Kodak — large tank, 1 min intervals
Verified Datasheet Report
T-Max RS 1+4 100 24.0 °C 7:00 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 18.0 °C 9:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 20.0 °C 8:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 21.0 °C 7:15 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 22.0 °C 6:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:30 Kodak — large tank, 1 min intervals
Verified Datasheet Report
D-76 stock 100 18.0 °C 7:30 —
Verified Datasheet Report
D-76 stock 100 20.0 °C 6:15 —
Verified Datasheet Report
D-76 stock 100 21.0 °C 5:45 —
Verified Datasheet Report
D-76 stock 100 22.0 °C 5:15 —
Verified Datasheet Report
D-76 stock 100 24.0 °C 4:15 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 18.0 °C 7:00 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 20.0 °C 5:45 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 21.0 °C 5:15 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 22.0 °C 4:45 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 24.0 °C 4:00 —
Verified Datasheet Report
T-Max Developer 1+4 100 20.0 °C 7:45 —
Verified Datasheet Report
T-Max Developer 1+4 100 21.0 °C 7:15 —
Verified Datasheet Report
T-Max Developer 1+4 100 22.0 °C 6:45 —
Verified Datasheet Report
T-Max Developer 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max Developer 1+7 100 24.0 °C 9:30 —
Verified Datasheet Report
T-Max Developer 1+9 100 24.0 °C 13:30 —
Verified Datasheet Report
T-Max RS 1+4 100 20.0 °C 7:45 —
Verified Datasheet Report
T-Max RS 1+4 100 21.0 °C 7:15 —
Verified Datasheet Report
T-Max RS 1+9 100 24.0 °C 12:30 —
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 11:45 —
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:45 —
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 8:45 —
Verified Datasheet Report
XTOL 1+1 100 22.0 °C 7:45 —
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 6:45 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 8:45 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 5:45 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:00 —
Verified Datasheet Report
D-76 stock 100 24.0 °C 4:15 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 18.0 °C 7:00 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 20.0 °C 5:45 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 21.0 °C 5:15 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 22.0 °C 4:45 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 24.0 °C 4:00 —
Verified Datasheet Report
T-Max Developer 1+4 100 20.0 °C 7:45 —
Verified Datasheet Report
T-Max Developer 1+4 100 21.0 °C 7:15 —
Verified Datasheet Report
T-Max Developer 1+4 100 22.0 °C 6:45 —
Verified Datasheet Report
T-Max Developer 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max Developer 1+7 100 24.0 °C 9:30 —
Verified Datasheet Report
T-Max Developer 1+9 100 24.0 °C 13:30 —
Verified Datasheet Report
T-Max RS 1+4 100 20.0 °C 7:45 —
Verified Datasheet Report
T-Max RS 1+4 100 21.0 °C 7:15 —
Verified Datasheet Report
T-Max RS 1+4 100 22.0 °C 6:45 —
Verified Datasheet Report
T-Max RS 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max RS 1+7 100 24.0 °C 8:30 —
Verified Datasheet Report
T-Max RS 1+9 100 24.0 °C 12:30 —
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 11:45 —
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:45 —
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 8:45 —
Verified Datasheet Report
XTOL 1+1 100 22.0 °C 7:45 —
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 6:45 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 8:45 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 5:45 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:00 —
Verified Datasheet Report
D-76 stock 100 24.0 °C 4:15 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 18.0 °C 7:00 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 20.0 °C 5:45 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 21.0 °C 5:15 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 22.0 °C 4:45 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 24.0 °C 4:00 —
Verified Datasheet Report
T-Max RS 1+4 100 20.0 °C 7:45 —
Verified Datasheet Report
T-Max RS 1+4 100 21.0 °C 7:15 —
Verified Datasheet Report
T-Max RS 1+4 100 22.0 °C 6:45 —
Verified Datasheet Report
T-Max RS 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max RS 1+7 100 24.0 °C 8:30 —
Verified Datasheet Report
T-Max RS 1+9 100 24.0 °C 12:30 —
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 11:45 —
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:45 —
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 9:00 —
Verified Datasheet Report
XTOL 1+1 100 22.0 °C 8:30 —
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 7:45 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 8:45 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 7:15 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 5:45 —
Verified Datasheet Report
D-76 1+1 100 18.0 °C 11:00 —
Verified Datasheet Report
D-76 1+1 100 20.0 °C 9:30 —
Verified Datasheet Report
D-76 1+1 100 21.0 °C 8:30 —
Verified Datasheet Report
D-76 1+1 100 22.0 °C 7:30 —
Verified Datasheet Report
D-76 1+1 100 24.0 °C 6:15 —
Verified Datasheet Report
D-76 stock 100 18.0 °C 7:30 —
Verified Datasheet Report
D-76 stock 100 20.0 °C 6:30 —
Verified Datasheet Report
D-76 stock 100 21.0 °C 5:30 —
Verified Datasheet Report
D-76 stock 100 22.0 °C 5:00 —
Verified Datasheet Report
D-76 stock 100 24.0 °C 4:15 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 18.0 °C 6:30 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 20.0 °C 6:00 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 21.0 °C 5:30 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 22.0 °C 5:00 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 24.0 °C 4:00 —
Verified Datasheet Report
T-Max Developer 1+4 100 20.0 °C 7:30 —
Verified Datasheet Report
T-Max Developer 1+4 100 21.0 °C 7:00 —
Verified Datasheet Report
T-Max Developer 1+4 100 22.0 °C 6:30 —
Verified Datasheet Report
T-Max Developer 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max Developer 1+7 100 24.0 °C 9:30 —
Verified Datasheet Report
T-Max Developer 1+9 100 24.0 °C 13:30 —
Verified Datasheet Report
T-Max RS 1+4 100 20.0 °C 8:00 —
Verified Datasheet Report
T-Max RS 1+4 100 21.0 °C 7:30 —
Verified Datasheet Report
T-Max RS 1+4 100 22.0 °C 7:00 —
Verified Datasheet Report
T-Max RS 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max RS 1+7 100 24.0 °C 8:30 —
Verified Datasheet Report
T-Max RS 1+9 100 24.0 °C 12:30 —
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 11:30 —
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:30 —
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 8:30 —
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 8:30 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 7:30 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 6:00 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:00 —
Verified Datasheet Report
D-76 1+1 100 18.0 °C 11:00 —
Verified Datasheet Report
D-76 1+1 100 20.0 °C 9:30 —
Verified Datasheet Report
D-76 1+1 100 21.0 °C 8:30 —
Verified Datasheet Report
D-76 1+1 100 22.0 °C 7:30 —
Verified Datasheet Report
D-76 1+1 100 24.0 °C 6:15 —
Verified Datasheet Report
D-76 stock 100 18.0 °C 7:30 —
Verified Datasheet Report
D-76 stock 100 20.0 °C 6:30 —
Verified Datasheet Report
D-76 stock 100 21.0 °C 5:30 —
Verified Datasheet Report
D-76 stock 100 22.0 °C 5:00 —
Verified Datasheet Report
D-76 stock 100 24.0 °C 4:15 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 18.0 °C 6:30 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 20.0 °C 6:00 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 21.0 °C 5:30 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 22.0 °C 5:00 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 24.0 °C 4:00 —
Verified Datasheet Report
T-Max Developer 1+4 100 20.0 °C 7:30 —
Verified Datasheet Report
T-Max Developer 1+4 100 21.0 °C 7:00 —
Verified Datasheet Report
T-Max Developer 1+4 100 22.0 °C 6:30 —
Verified Datasheet Report
T-Max Developer 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max Developer 1+7 100 24.0 °C 9:30 —
Verified Datasheet Report
T-Max Developer 1+9 100 24.0 °C 13:30 —
Verified Datasheet Report
T-Max RS 1+4 100 20.0 °C 8:00 —
Verified Datasheet Report
T-Max RS 1+4 100 21.0 °C 7:30 —
Verified Datasheet Report
T-Max RS 1+4 100 22.0 °C 7:00 —
Verified Datasheet Report
T-Max RS 1+4 100 24.0 °C 6:15 —
Verified Datasheet Report
T-Max RS 1+7 100 24.0 °C 8:30 —
Verified Datasheet Report
T-Max RS 1+9 100 24.0 °C 12:30 —
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 11:30 —
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:30 —
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 8:30 —
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 8:30 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 7:30 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:30 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 6:00 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 5:00 —
Verified Datasheet Report
D-76 stock 100 18.0 °C 6:45 —
Verified Datasheet Report
D-76 stock 100 20.0 °C 5:45 —
Verified Datasheet Report
D-76 stock 100 21.0 °C 5:15 —
Verified Datasheet Report
D-76 stock 100 22.0 °C 4:45 —
Verified Datasheet Report
D-76 stock 100 24.0 °C 4:00 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 18.0 °C 6:15 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 20.0 °C 5:30 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 21.0 °C 4:45 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 22.0 °C 4:30 —
Verified Datasheet Report
HC-110 Dilution B (1+31) 100 24.0 °C 3:45 —
Verified Datasheet Report
T-Max RS 1+4 100 20.0 °C 7:15 —
Verified Datasheet Report
T-Max RS 1+4 100 21.0 °C 6:45 —
Verified Datasheet Report
T-Max RS 1+4 100 22.0 °C 6:15 —
Verified Datasheet Report
T-Max RS 1+4 100 24.0 °C 5:45 —
Verified Datasheet Report
XTOL 1+1 100 18.0 °C 10:30 —
Verified Datasheet Report
XTOL 1+1 100 20.0 °C 9:00 —
Verified Datasheet Report
XTOL 1+1 100 21.0 °C 8:00 —
Verified Datasheet Report
XTOL 1+1 100 22.0 °C 7:00 —
Verified Datasheet Report
XTOL 1+1 100 24.0 °C 6:00 —
Verified Datasheet Report
XTOL stock 100 18.0 °C 8:00 —
Verified Datasheet Report
XTOL stock 100 20.0 °C 6:45 —
Verified Datasheet Report
XTOL stock 100 21.0 °C 6:00 —
Verified Datasheet Report
XTOL stock 100 22.0 °C 5:15 —
Verified Datasheet Report
XTOL stock 100 24.0 °C 4:30 —
Verified Datasheet Report

Development times by developer

13 developers

Kodak T-Max 100

Link to this page

Specification

BaseFilm base The clear, flexible support that carries the emulsion. Read more in the glossary ›
—
EmulsionEmulsion The light-sensitive layer of a film: tiny crystals of silver halide held in gelatin. Read more in the glossary ›
Tabular
Spectral sensitivitySpectral sensitivity Which colours of light a film responds to, and how strongly. Read more in the glossary ›
Panchromatic — what this means

Sensitive to the whole visible spectrum, so colours turn into greys roughly the way the eye weighs them. This is what almost every general-purpose black and white film is. It has to be loaded and developed in complete darkness — no safelight is safe for it.

Grain (RMS)Grain The visible, sand-like texture in a photograph that comes from the clumps of silver or dye that form the image. Read more in the glossary ›
—
Resolving power line pairs / mm
—
Maximum densityDensity How much light a negative, transparency or print blocks. Read more in the glossary ›
—
Latitude overExposure latitude How far a film can be over- or underexposed and still give a usable result. Read more in the glossary ›
—
Latitude under
—
First released
1986

A dash means the figure has not been read off a datasheet. Nothing here is estimated.

Compare with…

Help keep it right

Suggest a time or report a mistake.

Know a time for T-Max 100 that is missing here, or spotted one that is wrong? Tell us, with the source, and a curator will check it.

  • Sources only. We publish a time only when it has been read off a primary source: the maker’s datasheet or chart. A link to it is what lets us check yours.
  • Nothing goes up by itself. Every report is read by a person before anything on the page changes.
  • No account needed. Your name and email are optional, and only to reply to you.
What would you like to send?

A datasheet, the maker’s chart or technical publication. Forums and blogs can’t be checked the same way.

0 comments

Notes on how this behaves in practice — what it does in the field is worth as much as what the datasheet says.

Comments from visitors without an account are read by a moderator before they appear.

JPEG, PNG or WebP, up to 25 MB each. A frame is worth more than a paragraph.

Plain text. Up to 4,000 characters.

No comments yet. Be the first to say how it actually behaves.

0 reviews

Written by photographers, under their own profile — so you can see what they shoot before you weigh what they say.